Hero

Australian CVD Risk Calculator
Iteration3 - ci-build Australia flag

Australian CVD Risk Calculator - Local Development build (vIteration3) built by the FHIR (HL7® FHIR® Standard) Build Tools. See the Directory of published versions

Resource Profile: CVD Risk Sitting Blood Pressure

Official URL: https://www.cvdcheck.org.au/fhir/StructureDefinition/CVDRiskSittingBloodPressure Version: Iteration3
Draft as of 2025-05-19 Computable Name: CVDRiskSittingBloodPressure

Copyright/Legal: Copyright © 2024+ National Heart Foundation of Australia - All rights reserved. This content is not available under an open source licence.

This profile sets the expectations for an Observation resource to record a blood pressure result taken in the sitting position for use by the Aus CVD Risk-i application.

Profile specific implementation guidance

This profile is derived from AU Core Blood Presssure. It represents a blood pressure observation that was measured in a sitting position. Postural information is included as additional slices on Observation.code.coding, Observation.component[SystolicBP].code.coding, and Observation.component[DiastolicBP].code.coding.

Usage:

Formal Views of Profile Content

Description of Profiles, Differentials, Snapshots and how the different presentations work.

NameFlagsCard.TypeDescription & Constraintsdoco
.. Observation C 0..* AUCoreBloodPressure Sitting blood pressure result
dom-2: If the resource is contained in another resource, it SHALL NOT contain nested Resources
dom-3: If the resource is contained in another resource, it SHALL be referred to from elsewhere in the resource or SHALL refer to the containing resource
dom-4: If a resource is contained in another resource, it SHALL NOT have a meta.versionId or a meta.lastUpdated
dom-5: If a resource is contained in another resource, it SHALL NOT have a security label
dom-6: A resource should have narrative for robust management
obs-6: dataAbsentReason SHALL only be present if Observation.value[x] is not present
obs-7: If Observation.code is the same as an Observation.component.code then the value element associated with the code SHALL NOT be present
vs-2: If there is no component or hasMember element then either a value[x] or a data absent reason must be present.
... implicitRules ?!Σ 0..1 uri A set of rules under which this content was created
ele-1: All FHIR elements must have a @value or children
... modifierExtension ?! 0..* Extension Extensions that cannot be ignored
ele-1: All FHIR elements must have a @value or children
ext-1: Must have either extensions or value[x], not both
... status ?!SOΣ 1..1 code registered | preliminary | final | amended +
Binding: ObservationStatus (required)
ele-1: All FHIR elements must have a @value or children
Fixed Value: final
ObligationsActor
SHALL:populate-if-known AU Core Responder from AU Core Blood Pressure
SHALL:no-error AU Core Requester from AU Core Blood Pressure
SHALL:populate-if-known & SHALL:process AU Core ResponderAus CVD Risk Calculator Application
SHALL:no-error AU Core Requester
.... category:VSCat SO 1..1 CodeableConcept Classification of type of observation
Binding: ObservationCategoryCodes (preferred): Codes for high level observation categories.


ele-1: All FHIR elements must have a @value or children
ObligationsActor
SHALL:populate-if-known AU Core Responder from AU Core Blood Pressure
SHALL:no-error AU Core Requester from AU Core Blood Pressure
..... coding SOΣ 1..* Coding Code defined by a terminology system
ele-1: All FHIR elements must have a @value or children
ObligationsActor
SHALL:populate-if-known AU Core Responder from AU Core Blood Pressure
SHALL:no-error AU Core Requester from AU Core Blood Pressure
...... system SOΣ 1..1 uri Identity of the terminology system
ele-1: All FHIR elements must have a @value or children
Fixed Value: http://terminology.hl7.org/CodeSystem/observation-category
ObligationsActor
SHALL:populate-if-known AU Core Responder from AU Core Blood Pressure
SHALL:no-error AU Core Requester from AU Core Blood Pressure
...... code SOΣ 1..1 code Symbol in syntax defined by the system
ele-1: All FHIR elements must have a @value or children
Fixed Value: vital-signs
ObligationsActor
SHALL:populate-if-known AU Core Responder from AU Core Blood Pressure
SHALL:no-error AU Core Requester from AU Core Blood Pressure
... code SOΣ 1..1 CodeableConcept Blood Pressure
Binding: VitalSigns (extensible): This identifies the vital sign result type.


ele-1: All FHIR elements must have a @value or children
ObligationsActor
SHALL:populate-if-known AU Core Responder from AU Core Blood Pressure
SHALL:no-error AU Core Requester from AU Core Blood Pressure
SHALL:populate-if-known & SHALL:process AU Core ResponderAus CVD Risk Calculator Application
SHALL:no-error AU Core Requester
.... Slices for coding Σ 3..* Coding Code defined by a terminology system
Slice: Unordered, Open by value:code, value:system
ele-1: All FHIR elements must have a @value or children
..... coding:BPCode Σ 1..1 Coding Code defined by a terminology system
ele-1: All FHIR elements must have a @value or children
...... system Σ 1..1 uri Identity of the terminology system
ele-1: All FHIR elements must have a @value or children
Fixed Value: http://loinc.org
...... code Σ 1..1 code Symbol in syntax defined by the system
ele-1: All FHIR elements must have a @value or children
Fixed Value: 85354-9
..... coding:snomedBPCode Σ 1..1 Coding SNOMED CT Blood Pressure
ele-1: All FHIR elements must have a @value or children
...... system Σ 1..1 uri Identity of the terminology system
ele-1: All FHIR elements must have a @value or children
Fixed Value: http://snomed.info/sct
...... code Σ 1..1 code Symbol in syntax defined by the system
ele-1: All FHIR elements must have a @value or children
Fixed Value: 75367002
..... coding:snomedSittingBPCode SOΣ 1..1 Coding SNOMED CT Sitting Blood Pressure
ele-1: All FHIR elements must have a @value or children
ObligationsActor
SHALL:populate-if-known Aus CVD Risk Calculator Launch Server
SHALL:process Aus CVD Risk Calculator Application
...... system SOΣ 1..1 uri Identity of the terminology system
ele-1: All FHIR elements must have a @value or children
Fixed Value: http://snomed.info/sct
ObligationsActor
SHALL:populate-if-known Aus CVD Risk Calculator Launch Server
SHALL:process Aus CVD Risk Calculator Application
...... code SOΣ 1..1 code Symbol in syntax defined by the system
ele-1: All FHIR elements must have a @value or children
Fixed Value: 163035008
ObligationsActor
SHALL:populate-if-known Aus CVD Risk Calculator Launch Server
SHALL:process Aus CVD Risk Calculator Application
... subject SOΣ 1..1 Reference(AU Core Patient) Who and/or what the observation is about
ele-1: All FHIR elements must have a @value or children
ObligationsActor
SHALL:populate-if-known AU Core Responder from AU Core Blood Pressure
SHALL:no-error AU Core Requester from AU Core Blood Pressure
SHALL:populate-if-known & SHALL:process AU Core ResponderAus CVD Risk Calculator Application
SHALL:no-error AU Core Requester
... effective[x] SOΣC 1..1 dateTime Date, and optionally time, the observation was performed
ele-1: All FHIR elements must have a @value or children
vs-1: if Observation.effective[x] is dateTime and has a value then that value shall be precise to the day
ObligationsActor
SHALL:populate-if-known AU Core Responder from AU Core Blood Pressure
SHALL:no-error AU Core Requester from AU Core Blood Pressure
... Slices for value[x] SΣC 0..1 Quantity Vital Signs value are recorded using the Quantity data type. For supporting observations such as Cuff size could use other datatypes such as CodeableConcept.
Slice: Unordered, Closed by type:$this
ele-1: All FHIR elements must have a @value or children
... dataAbsentReason SOC 0..1 CodeableConcept Why the result is missing
Binding: DataAbsentReason (extensible): Codes specifying why the result (Observation.value[x]) is missing.


ele-1: All FHIR elements must have a @value or children
ObligationsActor
SHALL:populate-if-known AU Core Responder from AU Core Blood Pressure
SHALL:no-error AU Core Requester from AU Core Blood Pressure
... Slices for component SOΣC 2..* BackboneElement Used when reporting systolic and diastolic blood pressure.
Slice: Unordered, Open by value:code.coding.code, value:code.coding.system
ele-1: All FHIR elements must have a @value or children
vs-3: If there is no a value a data absent reason must be present
ObligationsActor
SHALL:populate-if-known AU Core Responder from AU Core Blood Pressure
SHALL:no-error AU Core Requester from AU Core Blood Pressure
SHALL:populate-if-known & SHALL:process AU Core ResponderAus CVD Risk Calculator Application
SHALL:no-error AU Core Requester
.... component:All Slices Content/Rules for all slices
..... modifierExtension ?!Σ 0..* Extension Extensions that cannot be ignored even if unrecognized
ele-1: All FHIR elements must have a @value or children
ext-1: Must have either extensions or value[x], not both
..... code SOΣ 1..1 CodeableConcept Type of component observation (code / type)
Binding: VitalSigns (extensible): This identifies the vital sign result type.


ele-1: All FHIR elements must have a @value or children
ObligationsActor
SHALL:populate-if-known AU Core Responder from AU Core Blood Pressure
SHALL:no-error AU Core Requester from AU Core Blood Pressure
..... value[x] SOΣC 0..1 Vital Sign Value recorded with UCUM
Binding: VitalSignsUnits (extensible): Common UCUM units for recording Vital Signs.


ele-1: All FHIR elements must have a @value or children
ObligationsActor
SHALL:populate-if-known AU Core Responder from AU Core Blood Pressure
SHALL:no-error AU Core Requester from AU Core Blood Pressure
...... valueQuantity Quantity
...... valueCodeableConcept CodeableConcept
...... valueString string
...... valueBoolean boolean
...... valueInteger integer
...... valueRange Range
...... valueRatio Ratio
...... valueSampledData SampledData
...... valueTime time
...... valueDateTime dateTime
...... valuePeriod Period
..... dataAbsentReason SOC 0..1 CodeableConcept Why the component result is missing
Binding: DataAbsentReason (extensible): Codes specifying why the result (Observation.value[x]) is missing.


ele-1: All FHIR elements must have a @value or children
ObligationsActor
SHALL:populate-if-known AU Core Responder from AU Core Blood Pressure
SHALL:no-error AU Core Requester from AU Core Blood Pressure
.... component:SystolicBP SOΣC 1..1 BackboneElement Systolic Blood Pressure
ele-1: All FHIR elements must have a @value or children
vs-3: If there is no a value a data absent reason must be present
ObligationsActor
SHALL:populate-if-known AU Core Responder from AU Core Blood Pressure
SHALL:no-error AU Core Requester from AU Core Blood Pressure
..... modifierExtension ?!Σ 0..* Extension Extensions that cannot be ignored even if unrecognized
ele-1: All FHIR elements must have a @value or children
ext-1: Must have either extensions or value[x], not both
..... code SOΣ 1..1 CodeableConcept Type of component observation (code / type)
Binding: VitalSigns (extensible): This identifies the vital sign result type.


ele-1: All FHIR elements must have a @value or children
ObligationsActor
SHALL:populate-if-known AU Core Responder from AU Core Blood Pressure
SHALL:no-error AU Core Requester from AU Core Blood Pressure
...... Slices for coding Σ 3..* Coding Systolic Blood Pressure
Slice: Unordered, Open by value:code, value:system
ele-1: All FHIR elements must have a @value or children
....... coding:SBPCode Σ 1..1 Coding Systolic Blood Pressure
ele-1: All FHIR elements must have a @value or children
........ system Σ 1..1 uri Identity of the terminology system
ele-1: All FHIR elements must have a @value or children
Fixed Value: http://loinc.org
........ code Σ 1..1 code Symbol in syntax defined by the system
ele-1: All FHIR elements must have a @value or children
Fixed Value: 8480-6
....... coding:snomedSBP Σ 1..1 Coding SNOMED CT Systolic Blood Pressure
ele-1: All FHIR elements must have a @value or children
........ system Σ 1..1 uri Identity of the terminology system
ele-1: All FHIR elements must have a @value or children
Fixed Value: http://snomed.info/sct
........ code Σ 1..1 code Symbol in syntax defined by the system
ele-1: All FHIR elements must have a @value or children
Fixed Value: 271649006
....... coding:snomedSittingSBP SOΣ 1..1 Coding SNOMED CT Sitting Systolic Blood Pressure
ele-1: All FHIR elements must have a @value or children
ObligationsActor
SHALL:populate-if-known Aus CVD Risk Calculator Launch Server
SHALL:process Aus CVD Risk Calculator Application
........ system SOΣ 1..1 uri Identity of the terminology system
ele-1: All FHIR elements must have a @value or children
Fixed Value: http://snomed.info/sct
ObligationsActor
SHALL:populate-if-known Aus CVD Risk Calculator Launch Server
SHALL:process Aus CVD Risk Calculator Application
........ code SOΣ 1..1 code Symbol in syntax defined by the system
ele-1: All FHIR elements must have a @value or children
Fixed Value: 407554009
ObligationsActor
SHALL:populate-if-known Aus CVD Risk Calculator Launch Server
SHALL:process Aus CVD Risk Calculator Application
..... value[x] SOΣC 0..1 Quantity Vital Sign Value recorded with UCUM
Binding: VitalSignsUnits (extensible): Common UCUM units for recording Vital Signs.


ele-1: All FHIR elements must have a @value or children
ObligationsActor
SHALL:populate-if-known AU Core Responder from AU Core Blood Pressure
SHALL:no-error AU Core Requester from AU Core Blood Pressure
...... value SOΣ 1..1 decimal Numerical value (with implicit precision)
ele-1: All FHIR elements must have a @value or children
ObligationsActor
SHALL:populate-if-known AU Core Responder from AU Core Blood Pressure
SHALL:no-error AU Core Requester from AU Core Blood Pressure
...... comparator ?!Σ 0..1 code < | <= | >= | > - how to understand the value
Binding: QuantityComparator (required): How the Quantity should be understood and represented.


ele-1: All FHIR elements must have a @value or children
...... unit SOΣ 1..1 string Unit representation
ele-1: All FHIR elements must have a @value or children
ObligationsActor
SHALL:populate-if-known AU Core Responder from AU Core Blood Pressure
SHALL:no-error AU Core Requester from AU Core Blood Pressure
...... system SOΣC 1..1 uri System that defines coded unit form
ele-1: All FHIR elements must have a @value or children
Fixed Value: http://unitsofmeasure.org
ObligationsActor
SHALL:populate-if-known AU Core Responder from AU Core Blood Pressure
SHALL:no-error AU Core Requester from AU Core Blood Pressure
...... code SOΣ 1..1 code Coded responses from the common UCUM units for vital signs value set.
ele-1: All FHIR elements must have a @value or children
Fixed Value: mm[Hg]
ObligationsActor
SHALL:populate-if-known AU Core Responder from AU Core Blood Pressure
SHALL:no-error AU Core Requester from AU Core Blood Pressure
..... dataAbsentReason SOC 0..1 CodeableConcept Why the component result is missing
Binding: DataAbsentReason (extensible): Codes specifying why the result (Observation.value[x]) is missing.


ele-1: All FHIR elements must have a @value or children
ObligationsActor
SHALL:populate-if-known AU Core Responder from AU Core Blood Pressure
SHALL:no-error AU Core Requester from AU Core Blood Pressure
.... component:DiastolicBP SOΣC 1..1 BackboneElement Diastolic Blood Pressure
ele-1: All FHIR elements must have a @value or children
vs-3: If there is no a value a data absent reason must be present
ObligationsActor
SHALL:populate-if-known AU Core Responder from AU Core Blood Pressure
SHALL:no-error AU Core Requester from AU Core Blood Pressure
..... modifierExtension ?!Σ 0..* Extension Extensions that cannot be ignored even if unrecognized
ele-1: All FHIR elements must have a @value or children
ext-1: Must have either extensions or value[x], not both
..... code SOΣ 1..1 CodeableConcept Type of component observation (code / type)
Binding: VitalSigns (extensible): This identifies the vital sign result type.


ele-1: All FHIR elements must have a @value or children
ObligationsActor
SHALL:populate-if-known AU Core Responder from AU Core Blood Pressure
SHALL:no-error AU Core Requester from AU Core Blood Pressure
...... Slices for coding Σ 3..* Coding Diastolic Blood Pressure
Slice: Unordered, Open by value:code, value:system
ele-1: All FHIR elements must have a @value or children
....... coding:DBPCode Σ 1..1 Coding Diastolic Blood Pressure
ele-1: All FHIR elements must have a @value or children
........ system Σ 1..1 uri Identity of the terminology system
ele-1: All FHIR elements must have a @value or children
Fixed Value: http://loinc.org
........ code Σ 1..1 code Symbol in syntax defined by the system
ele-1: All FHIR elements must have a @value or children
Fixed Value: 8462-4
....... coding:snomedDBP Σ 1..1 Coding SNOMED CT Diastolic Blood Pressure
ele-1: All FHIR elements must have a @value or children
........ system Σ 1..1 uri Identity of the terminology system
ele-1: All FHIR elements must have a @value or children
Fixed Value: http://snomed.info/sct
........ code Σ 1..1 code Symbol in syntax defined by the system
ele-1: All FHIR elements must have a @value or children
Fixed Value: 271650006
....... coding:snomedSittingDBP SOΣ 1..1 Coding SNOMED CT Sitting Diastolic Blood Pressure
ele-1: All FHIR elements must have a @value or children
ObligationsActor
SHALL:populate-if-known Aus CVD Risk Calculator Launch Server
SHALL:process Aus CVD Risk Calculator Application
........ system SOΣ 1..1 uri Identity of the terminology system
ele-1: All FHIR elements must have a @value or children
Fixed Value: http://snomed.info/sct
ObligationsActor
SHALL:populate-if-known Aus CVD Risk Calculator Launch Server
SHALL:no-error Aus CVD Risk Calculator Application
........ code SOΣ 1..1 code Symbol in syntax defined by the system
ele-1: All FHIR elements must have a @value or children
Fixed Value: 407555005
ObligationsActor
SHALL:populate-if-known Aus CVD Risk Calculator Launch Server
SHALL:no-error Aus CVD Risk Calculator Application
..... value[x] SOΣC 0..1 Quantity Vital Sign Value recorded with UCUM
Binding: VitalSignsUnits (extensible): Common UCUM units for recording Vital Signs.


ele-1: All FHIR elements must have a @value or children
ObligationsActor
SHALL:populate-if-known AU Core Responder from AU Core Blood Pressure
SHALL:no-error AU Core Requester from AU Core Blood Pressure
...... value SOΣ 1..1 decimal Numerical value (with implicit precision)
ele-1: All FHIR elements must have a @value or children
ObligationsActor
SHALL:populate-if-known AU Core Responder from AU Core Blood Pressure
SHALL:no-error AU Core Requester from AU Core Blood Pressure
...... comparator ?!Σ 0..1 code < | <= | >= | > - how to understand the value
Binding: QuantityComparator (required): How the Quantity should be understood and represented.


ele-1: All FHIR elements must have a @value or children
...... unit SOΣ 1..1 string Unit representation
ele-1: All FHIR elements must have a @value or children
ObligationsActor
SHALL:populate-if-known AU Core Responder from AU Core Blood Pressure
SHALL:no-error AU Core Requester from AU Core Blood Pressure
...... system SOΣC 1..1 uri System that defines coded unit form
ele-1: All FHIR elements must have a @value or children
Fixed Value: http://unitsofmeasure.org
ObligationsActor
SHALL:populate-if-known AU Core Responder from AU Core Blood Pressure
SHALL:no-error AU Core Requester from AU Core Blood Pressure
...... code SOΣ 1..1 code Coded responses from the common UCUM units for vital signs value set.
ele-1: All FHIR elements must have a @value or children
Fixed Value: mm[Hg]
ObligationsActor
SHALL:populate-if-known AU Core Responder from AU Core Blood Pressure
SHALL:no-error AU Core Requester from AU Core Blood Pressure
..... dataAbsentReason SOC 0..1 CodeableConcept Why the component result is missing
Binding: DataAbsentReason (extensible): Codes specifying why the result (Observation.value[x]) is missing.


ele-1: All FHIR elements must have a @value or children
ObligationsActor
SHALL:populate-if-known AU Core Responder from AU Core Blood Pressure
SHALL:no-error AU Core Requester from AU Core Blood Pressure

doco Documentation for this format

Terminology Bindings

PathConformanceValueSet / CodeURI
Observation.statusrequiredFixed Value: final
http://hl7.org/fhir/ValueSet/observation-status|4.0.1
from the FHIR Standard
Observation.categorypreferredObservationCategoryCodes
http://hl7.org/fhir/ValueSet/observation-category
from the FHIR Standard
Observation.category:VSCatpreferredObservationCategoryCodes
http://hl7.org/fhir/ValueSet/observation-category
from the FHIR Standard
Observation.codeextensibleVitalSigns
http://hl7.org/fhir/ValueSet/observation-vitalsignresult
from the FHIR Standard
Observation.dataAbsentReasonextensibleDataAbsentReason
http://hl7.org/fhir/ValueSet/data-absent-reason
from the FHIR Standard
Observation.component.codeextensibleVitalSigns
http://hl7.org/fhir/ValueSet/observation-vitalsignresult
from the FHIR Standard
Observation.component.value[x]extensibleVitalSignsUnits
http://hl7.org/fhir/ValueSet/ucum-vitals-common|4.0.1
from the FHIR Standard
Observation.component.dataAbsentReasonextensibleDataAbsentReason
http://hl7.org/fhir/ValueSet/data-absent-reason
from the FHIR Standard
Observation.component:SystolicBP.codeextensibleVitalSigns
http://hl7.org/fhir/ValueSet/observation-vitalsignresult
from the FHIR Standard
Observation.component:SystolicBP.value[x]extensibleVitalSignsUnits
http://hl7.org/fhir/ValueSet/ucum-vitals-common|4.0.1
from the FHIR Standard
Observation.component:SystolicBP.value[x].comparatorrequiredQuantityComparator
http://hl7.org/fhir/ValueSet/quantity-comparator|4.0.1
from the FHIR Standard
Observation.component:SystolicBP.dataAbsentReasonextensibleDataAbsentReason
http://hl7.org/fhir/ValueSet/data-absent-reason
from the FHIR Standard
Observation.component:DiastolicBP.codeextensibleVitalSigns
http://hl7.org/fhir/ValueSet/observation-vitalsignresult
from the FHIR Standard
Observation.component:DiastolicBP.value[x]extensibleVitalSignsUnits
http://hl7.org/fhir/ValueSet/ucum-vitals-common|4.0.1
from the FHIR Standard
Observation.component:DiastolicBP.value[x].comparatorrequiredQuantityComparator
http://hl7.org/fhir/ValueSet/quantity-comparator|4.0.1
from the FHIR Standard
Observation.component:DiastolicBP.dataAbsentReasonextensibleDataAbsentReason
http://hl7.org/fhir/ValueSet/data-absent-reason
from the FHIR Standard

Constraints

IdGradePath(s)DetailsRequirements
dom-2errorObservationIf the resource is contained in another resource, it SHALL NOT contain nested Resources
: contained.contained.empty()
dom-3errorObservationIf the resource is contained in another resource, it SHALL be referred to from elsewhere in the resource or SHALL refer to the containing resource
: contained.where((('#'+id in (%resource.descendants().reference | %resource.descendants().as(canonical) | %resource.descendants().as(uri) | %resource.descendants().as(url))) or descendants().where(reference = '#').exists() or descendants().where(as(canonical) = '#').exists() or descendants().where(as(canonical) = '#').exists()).not()).trace('unmatched', id).empty()
dom-4errorObservationIf a resource is contained in another resource, it SHALL NOT have a meta.versionId or a meta.lastUpdated
: contained.meta.versionId.empty() and contained.meta.lastUpdated.empty()
dom-5errorObservationIf a resource is contained in another resource, it SHALL NOT have a security label
: contained.meta.security.empty()
dom-6best practiceObservationA resource should have narrative for robust management
: text.`div`.exists()
ele-1error**ALL** elementsAll FHIR elements must have a @value or children
: hasValue() or (children().count() > id.count())
ext-1error**ALL** extensionsMust have either extensions or value[x], not both
: extension.exists() != value.exists()
obs-6errorObservationdataAbsentReason SHALL only be present if Observation.value[x] is not present
: dataAbsentReason.empty() or value.empty()
obs-7errorObservationIf Observation.code is the same as an Observation.component.code then the value element associated with the code SHALL NOT be present
: value.empty() or component.code.where(coding.intersect(%resource.code.coding).exists()).empty()
vs-1errorObservation.effective[x]if Observation.effective[x] is dateTime and has a value then that value shall be precise to the day
: $this is dateTime implies $this.toString().length() >= 10
vs-2errorObservationIf there is no component or hasMember element then either a value[x] or a data absent reason must be present.
: (component.empty() and hasMember.empty()) implies (dataAbsentReason.exists() or value.exists())
vs-3errorObservation.component, Observation.component:SystolicBP, Observation.component:DiastolicBPIf there is no a value a data absent reason must be present
: value.exists() or dataAbsentReason.exists()

This structure is derived from AUCoreBloodPressure

NameFlagsCard.TypeDescription & Constraintsdoco
.. Observation 0..* AUCoreBloodPressure Sitting blood pressure result
... status O 1..1 code registered | preliminary | final | amended +
Fixed Value: final
ObligationsActor
SHALL:populate-if-known & SHALL:process AU Core ResponderAus CVD Risk Calculator Application
SHALL:no-error AU Core Requester
... code O 1..1 CodeableConcept Blood Pressure
ObligationsActor
SHALL:populate-if-known & SHALL:process AU Core ResponderAus CVD Risk Calculator Application
SHALL:no-error AU Core Requester
.... coding 3..* Coding Code defined by a terminology system
.... Slices for coding Content/Rules for all slices
..... coding:snomedSittingBPCode SO 1..1 Coding SNOMED CT Sitting Blood Pressure
ObligationsActor
SHALL:populate-if-known Aus CVD Risk Calculator Launch Server
SHALL:process Aus CVD Risk Calculator Application
...... system SO 1..1 uri Identity of the terminology system
Fixed Value: http://snomed.info/sct
ObligationsActor
SHALL:populate-if-known Aus CVD Risk Calculator Launch Server
SHALL:process Aus CVD Risk Calculator Application
...... code SO 1..1 code Symbol in syntax defined by the system
Fixed Value: 163035008
ObligationsActor
SHALL:populate-if-known Aus CVD Risk Calculator Launch Server
SHALL:process Aus CVD Risk Calculator Application
... subject O 1..1 Reference(AU Core Patient) Who and/or what the observation is about
ObligationsActor
SHALL:populate-if-known & SHALL:process AU Core ResponderAus CVD Risk Calculator Application
SHALL:no-error AU Core Requester
... Slices for component Content/Rules for all slices
.... component:SystolicBP 1..1 BackboneElement Systolic Blood Pressure
..... code
...... coding 3..* Coding Systolic Blood Pressure
...... Slices for coding Content/Rules for all slices
....... coding:snomedSittingSBP SO 1..1 Coding SNOMED CT Sitting Systolic Blood Pressure
ObligationsActor
SHALL:populate-if-known Aus CVD Risk Calculator Launch Server
SHALL:process Aus CVD Risk Calculator Application
........ system SO 1..1 uri Identity of the terminology system
Fixed Value: http://snomed.info/sct
ObligationsActor
SHALL:populate-if-known Aus CVD Risk Calculator Launch Server
SHALL:process Aus CVD Risk Calculator Application
........ code SO 1..1 code Symbol in syntax defined by the system
Fixed Value: 407554009
ObligationsActor
SHALL:populate-if-known Aus CVD Risk Calculator Launch Server
SHALL:process Aus CVD Risk Calculator Application
.... component:DiastolicBP 1..1 BackboneElement Diastolic Blood Pressure
..... code
...... coding 3..* Coding Diastolic Blood Pressure
...... Slices for coding Content/Rules for all slices
....... coding:snomedSittingDBP SO 1..1 Coding SNOMED CT Sitting Diastolic Blood Pressure
ObligationsActor
SHALL:populate-if-known Aus CVD Risk Calculator Launch Server
SHALL:process Aus CVD Risk Calculator Application
........ system SO 1..1 uri Identity of the terminology system
Fixed Value: http://snomed.info/sct
ObligationsActor
SHALL:populate-if-known Aus CVD Risk Calculator Launch Server
SHALL:no-error Aus CVD Risk Calculator Application
........ code SO 1..1 code Symbol in syntax defined by the system
Fixed Value: 407555005
ObligationsActor
SHALL:populate-if-known Aus CVD Risk Calculator Launch Server
SHALL:no-error Aus CVD Risk Calculator Application

doco Documentation for this format
NameFlagsCard.TypeDescription & Constraintsdoco
.. Observation C 0..* AUCoreBloodPressure Sitting blood pressure result
obs-6: dataAbsentReason SHALL only be present if Observation.value[x] is not present
obs-7: If Observation.code is the same as an Observation.component.code then the value element associated with the code SHALL NOT be present
vs-2: If there is no component or hasMember element then either a value[x] or a data absent reason must be present.
... id Σ 0..1 id Logical id of this artifact
... meta Σ 0..1 Meta Metadata about the resource
... implicitRules ?!Σ 0..1 uri A set of rules under which this content was created
... language 0..1 code Language of the resource content
Binding: CommonLanguages (preferred): A human language.

Additional BindingsPurpose
AllLanguages Max Binding
... text 0..1 Narrative Text summary of the resource, for human interpretation
... contained 0..* Resource Contained, inline Resources
... extension 0..* Extension Additional content defined by implementations
... modifierExtension ?! 0..* Extension Extensions that cannot be ignored
... identifier Σ 0..* Identifier Business Identifier for observation
... basedOn Σ 0..* Reference(CarePlan | DeviceRequest | ImmunizationRecommendation | MedicationRequest | NutritionOrder | ServiceRequest) Fulfills plan, proposal or order
... partOf Σ 0..* Reference(MedicationAdministration | MedicationDispense | MedicationStatement | Procedure | Immunization | ImagingStudy) Part of referenced event
... status ?!SOΣ 1..1 code registered | preliminary | final | amended +
Binding: ObservationStatus (required)
Fixed Value: final
ObligationsActor
SHALL:populate-if-known AU Core Responder from AU Core Blood Pressure
SHALL:no-error AU Core Requester from AU Core Blood Pressure
SHALL:populate-if-known & SHALL:process AU Core ResponderAus CVD Risk Calculator Application
SHALL:no-error AU Core Requester
... Slices for category SO 1..* CodeableConcept Classification of type of observation
Slice: Unordered, Open by value:coding.code, value:coding.system
Binding: ObservationCategoryCodes (preferred): Codes for high level observation categories.


ObligationsActor
SHALL:populate-if-known AU Core Responder from AU Core Blood Pressure
SHALL:no-error AU Core Requester from AU Core Blood Pressure
.... category:VSCat SO 1..1 CodeableConcept Classification of type of observation
Binding: ObservationCategoryCodes (preferred): Codes for high level observation categories.


ObligationsActor
SHALL:populate-if-known AU Core Responder from AU Core Blood Pressure
SHALL:no-error AU Core Requester from AU Core Blood Pressure
..... id 0..1 string Unique id for inter-element referencing
..... extension 0..* Extension Additional content defined by implementations
Slice: Unordered, Open by value:url
..... coding SOΣ 1..* Coding Code defined by a terminology system
ObligationsActor
SHALL:populate-if-known AU Core Responder from AU Core Blood Pressure
SHALL:no-error AU Core Requester from AU Core Blood Pressure
...... id 0..1 string Unique id for inter-element referencing
...... extension 0..* Extension Additional content defined by implementations
Slice: Unordered, Open by value:url
...... system SOΣ 1..1 uri Identity of the terminology system
Fixed Value: http://terminology.hl7.org/CodeSystem/observation-category
ObligationsActor
SHALL:populate-if-known AU Core Responder from AU Core Blood Pressure
SHALL:no-error AU Core Requester from AU Core Blood Pressure
...... version Σ 0..1 string Version of the system - if relevant
...... code SOΣ 1..1 code Symbol in syntax defined by the system
Fixed Value: vital-signs
ObligationsActor
SHALL:populate-if-known AU Core Responder from AU Core Blood Pressure
SHALL:no-error AU Core Requester from AU Core Blood Pressure
...... display Σ 0..1 string Representation defined by the system
...... userSelected Σ 0..1 boolean If this coding was chosen directly by the user
..... text Σ 0..1 string Plain text representation of the concept
... code SOΣ 1..1 CodeableConcept Blood Pressure
Binding: VitalSigns (extensible): This identifies the vital sign result type.

ObligationsActor
SHALL:populate-if-known AU Core Responder from AU Core Blood Pressure
SHALL:no-error AU Core Requester from AU Core Blood Pressure
SHALL:populate-if-known & SHALL:process AU Core ResponderAus CVD Risk Calculator Application
SHALL:no-error AU Core Requester
.... id 0..1 string Unique id for inter-element referencing
.... extension 0..* Extension Additional content defined by implementations
Slice: Unordered, Open by value:url
.... Slices for coding Σ 3..* Coding Code defined by a terminology system
Slice: Unordered, Open by value:code, value:system
..... coding:BPCode Σ 1..1 Coding Code defined by a terminology system
...... id 0..1 string Unique id for inter-element referencing
...... extension 0..* Extension Additional content defined by implementations
Slice: Unordered, Open by value:url
...... system Σ 1..1 uri Identity of the terminology system
Fixed Value: http://loinc.org
...... version Σ 0..1 string Version of the system - if relevant
...... code Σ 1..1 code Symbol in syntax defined by the system
Fixed Value: 85354-9
...... display Σ 0..1 string Representation defined by the system
...... userSelected Σ 0..1 boolean If this coding was chosen directly by the user
..... coding:snomedBPCode Σ 1..1 Coding SNOMED CT Blood Pressure
...... id 0..1 string Unique id for inter-element referencing
...... extension 0..* Extension Additional content defined by implementations
Slice: Unordered, Open by value:url
...... system Σ 1..1 uri Identity of the terminology system
Fixed Value: http://snomed.info/sct
...... version Σ 0..1 string Version of the system - if relevant
...... code Σ 1..1 code Symbol in syntax defined by the system
Fixed Value: 75367002
...... display Σ 0..1 string Representation defined by the system
...... userSelected Σ 0..1 boolean If this coding was chosen directly by the user
..... coding:snomedSittingBPCode SOΣ 1..1 Coding SNOMED CT Sitting Blood Pressure
ObligationsActor
SHALL:populate-if-known Aus CVD Risk Calculator Launch Server
SHALL:process Aus CVD Risk Calculator Application
...... id 0..1 string Unique id for inter-element referencing
...... extension 0..* Extension Additional content defined by implementations
Slice: Unordered, Open by value:url
...... system SOΣ 1..1 uri Identity of the terminology system
Fixed Value: http://snomed.info/sct
ObligationsActor
SHALL:populate-if-known Aus CVD Risk Calculator Launch Server
SHALL:process Aus CVD Risk Calculator Application
...... version Σ 0..1 string Version of the system - if relevant
...... code SOΣ 1..1 code Symbol in syntax defined by the system
Fixed Value: 163035008
ObligationsActor
SHALL:populate-if-known Aus CVD Risk Calculator Launch Server
SHALL:process Aus CVD Risk Calculator Application
...... display Σ 0..1 string Representation defined by the system
...... userSelected Σ 0..1 boolean If this coding was chosen directly by the user
.... text Σ 0..1 string Plain text representation of the concept
... subject SOΣ 1..1 Reference(AU Core Patient) Who and/or what the observation is about
ObligationsActor
SHALL:populate-if-known AU Core Responder from AU Core Blood Pressure
SHALL:no-error AU Core Requester from AU Core Blood Pressure
SHALL:populate-if-known & SHALL:process AU Core ResponderAus CVD Risk Calculator Application
SHALL:no-error AU Core Requester
... focus Σ 0..* Reference(Resource) What the observation is about, when it is not about the subject of record
... encounter Σ 0..1 Reference(Encounter) Healthcare event during which this observation is made
... effective[x] SOΣC 1..1 dateTime Date, and optionally time, the observation was performed
vs-1: if Observation.effective[x] is dateTime and has a value then that value shall be precise to the day
ObligationsActor
SHALL:populate-if-known AU Core Responder from AU Core Blood Pressure
SHALL:no-error AU Core Requester from AU Core Blood Pressure
... issued Σ 0..1 instant Date/Time this version was made available
... performer Σ 0..* Reference(Practitioner | PractitionerRole | Organization | CareTeam | Patient | RelatedPerson) Who is responsible for the observation
... Slices for value[x] SΣC 0..1 Quantity Vital Signs value are recorded using the Quantity data type. For supporting observations such as Cuff size could use other datatypes such as CodeableConcept.
Slice: Unordered, Closed by type:$this
... dataAbsentReason SOC 0..1 CodeableConcept Why the result is missing
Binding: DataAbsentReason (extensible): Codes specifying why the result (Observation.value[x]) is missing.

ObligationsActor
SHALL:populate-if-known AU Core Responder from AU Core Blood Pressure
SHALL:no-error AU Core Requester from AU Core Blood Pressure
... interpretation 0..* CodeableConcept High, low, normal, etc.
Binding: ObservationInterpretationCodes (extensible): Codes identifying interpretations of observations.


... note 0..* Annotation Comments about the observation
... bodySite C 0..1 CodeableConcept Observed body part
Binding: Body Site . (extensible)
au-core-obs-01: If a coded body site is provided, at least one coding shall be from SNOMED CT
... method 0..1 CodeableConcept How it was done
Binding: ObservationMethods (example): Methods for simple observations.

... specimen 0..1 Reference(Specimen) Specimen used for this observation
... device 0..1 Reference(Device | DeviceMetric) (Measurement) Device
... referenceRange C 0..* BackboneElement Provides guide for interpretation
obs-3: Must have at least a low or a high or text
.... id 0..1 string Unique id for inter-element referencing
.... extension 0..* Extension Additional content defined by implementations
.... modifierExtension ?!Σ 0..* Extension Extensions that cannot be ignored even if unrecognized
.... low C 0..1 SimpleQuantity Low Range, if relevant
.... high C 0..1 SimpleQuantity High Range, if relevant
.... type 0..1 CodeableConcept Reference range qualifier
Binding: ObservationReferenceRangeMeaningCodes (preferred): Code for the meaning of a reference range.

.... appliesTo 0..* CodeableConcept Reference range population
Binding: ObservationReferenceRangeAppliesToCodes (example): Codes identifying the population the reference range applies to.


.... age 0..1 Range Applicable age range, if relevant
.... text 0..1 string Text based reference range in an observation
... hasMember Σ 0..* Reference(QuestionnaireResponse | MolecularSequence | Vital Signs Profile) Used when reporting vital signs panel components
... derivedFrom Σ 0..* Reference(DocumentReference | ImagingStudy | Media | QuestionnaireResponse | MolecularSequence | Vital Signs Profile) Related measurements the observation is made from
... Slices for component SOΣC 2..* BackboneElement Used when reporting systolic and diastolic blood pressure.
Slice: Unordered, Open by value:code.coding.code, value:code.coding.system
vs-3: If there is no a value a data absent reason must be present
ObligationsActor
SHALL:populate-if-known AU Core Responder from AU Core Blood Pressure
SHALL:no-error AU Core Requester from AU Core Blood Pressure
SHALL:populate-if-known & SHALL:process AU Core ResponderAus CVD Risk Calculator Application
SHALL:no-error AU Core Requester
.... component:All Slices Content/Rules for all slices
..... id 0..1 string Unique id for inter-element referencing
..... extension 0..* Extension Additional content defined by implementations
..... modifierExtension ?!Σ 0..* Extension Extensions that cannot be ignored even if unrecognized
..... code SOΣ 1..1 CodeableConcept Type of component observation (code / type)
Binding: VitalSigns (extensible): This identifies the vital sign result type.

ObligationsActor
SHALL:populate-if-known AU Core Responder from AU Core Blood Pressure
SHALL:no-error AU Core Requester from AU Core Blood Pressure
..... value[x] SOΣC 0..1 Vital Sign Value recorded with UCUM
Binding: VitalSignsUnits (extensible): Common UCUM units for recording Vital Signs.

ObligationsActor
SHALL:populate-if-known AU Core Responder from AU Core Blood Pressure
SHALL:no-error AU Core Requester from AU Core Blood Pressure
...... valueQuantity Quantity
...... valueCodeableConcept CodeableConcept
...... valueString string
...... valueBoolean boolean
...... valueInteger integer
...... valueRange Range
...... valueRatio Ratio
...... valueSampledData SampledData
...... valueTime time
...... valueDateTime dateTime
...... valuePeriod Period
..... dataAbsentReason SOC 0..1 CodeableConcept Why the component result is missing
Binding: DataAbsentReason (extensible): Codes specifying why the result (Observation.value[x]) is missing.

ObligationsActor
SHALL:populate-if-known AU Core Responder from AU Core Blood Pressure
SHALL:no-error AU Core Requester from AU Core Blood Pressure
..... interpretation 0..* CodeableConcept High, low, normal, etc.
Binding: ObservationInterpretationCodes (extensible): Codes identifying interpretations of observations.


..... referenceRange 0..* See referenceRange (Observation) Provides guide for interpretation of component result
.... component:SystolicBP SOΣC 1..1 BackboneElement Systolic Blood Pressure
vs-3: If there is no a value a data absent reason must be present
ObligationsActor
SHALL:populate-if-known AU Core Responder from AU Core Blood Pressure
SHALL:no-error AU Core Requester from AU Core Blood Pressure
..... id 0..1 string Unique id for inter-element referencing
..... extension 0..* Extension Additional content defined by implementations
..... modifierExtension ?!Σ 0..* Extension Extensions that cannot be ignored even if unrecognized
..... code SOΣ 1..1 CodeableConcept Type of component observation (code / type)
Binding: VitalSigns (extensible): This identifies the vital sign result type.

ObligationsActor
SHALL:populate-if-known AU Core Responder from AU Core Blood Pressure
SHALL:no-error AU Core Requester from AU Core Blood Pressure
...... id 0..1 string Unique id for inter-element referencing
...... extension 0..* Extension Additional content defined by implementations
Slice: Unordered, Open by value:url
...... Slices for coding Σ 3..* Coding Systolic Blood Pressure
Slice: Unordered, Open by value:code, value:system
....... coding:SBPCode Σ 1..1 Coding Systolic Blood Pressure
........ id 0..1 string Unique id for inter-element referencing
........ extension 0..* Extension Additional content defined by implementations
Slice: Unordered, Open by value:url
........ system Σ 1..1 uri Identity of the terminology system
Fixed Value: http://loinc.org
........ version Σ 0..1 string Version of the system - if relevant
........ code Σ 1..1 code Symbol in syntax defined by the system
Fixed Value: 8480-6
........ display Σ 0..1 string Representation defined by the system
........ userSelected Σ 0..1 boolean If this coding was chosen directly by the user
....... coding:snomedSBP Σ 1..1 Coding SNOMED CT Systolic Blood Pressure
........ id 0..1 string Unique id for inter-element referencing
........ extension 0..* Extension Additional content defined by implementations
Slice: Unordered, Open by value:url
........ system Σ 1..1 uri Identity of the terminology system
Fixed Value: http://snomed.info/sct
........ version Σ 0..1 string Version of the system - if relevant
........ code Σ 1..1 code Symbol in syntax defined by the system
Fixed Value: 271649006
........ display Σ 0..1 string Representation defined by the system
........ userSelected Σ 0..1 boolean If this coding was chosen directly by the user
....... coding:snomedSittingSBP SOΣ 1..1 Coding SNOMED CT Sitting Systolic Blood Pressure
ObligationsActor
SHALL:populate-if-known Aus CVD Risk Calculator Launch Server
SHALL:process Aus CVD Risk Calculator Application
........ id 0..1 string Unique id for inter-element referencing
........ extension 0..* Extension Additional content defined by implementations
Slice: Unordered, Open by value:url
........ system SOΣ 1..1 uri Identity of the terminology system
Fixed Value: http://snomed.info/sct
ObligationsActor
SHALL:populate-if-known Aus CVD Risk Calculator Launch Server
SHALL:process Aus CVD Risk Calculator Application
........ version Σ 0..1 string Version of the system - if relevant
........ code SOΣ 1..1 code Symbol in syntax defined by the system
Fixed Value: 407554009
ObligationsActor
SHALL:populate-if-known Aus CVD Risk Calculator Launch Server
SHALL:process Aus CVD Risk Calculator Application
........ display Σ 0..1 string Representation defined by the system
........ userSelected Σ 0..1 boolean If this coding was chosen directly by the user
...... text Σ 0..1 string Plain text representation of the concept
..... value[x] SOΣC 0..1 Quantity Vital Sign Value recorded with UCUM
Binding: VitalSignsUnits (extensible): Common UCUM units for recording Vital Signs.

ObligationsActor
SHALL:populate-if-known AU Core Responder from AU Core Blood Pressure
SHALL:no-error AU Core Requester from AU Core Blood Pressure
...... id 0..1 string Unique id for inter-element referencing
...... extension 0..* Extension Additional content defined by implementations
Slice: Unordered, Open by value:url
...... value SOΣ 1..1 decimal Numerical value (with implicit precision)
ObligationsActor
SHALL:populate-if-known AU Core Responder from AU Core Blood Pressure
SHALL:no-error AU Core Requester from AU Core Blood Pressure
...... comparator ?!Σ 0..1 code < | <= | >= | > - how to understand the value
Binding: QuantityComparator (required): How the Quantity should be understood and represented.

...... unit SOΣ 1..1 string Unit representation
ObligationsActor
SHALL:populate-if-known AU Core Responder from AU Core Blood Pressure
SHALL:no-error AU Core Requester from AU Core Blood Pressure
...... system SOΣC 1..1 uri System that defines coded unit form
Fixed Value: http://unitsofmeasure.org
ObligationsActor
SHALL:populate-if-known AU Core Responder from AU Core Blood Pressure
SHALL:no-error AU Core Requester from AU Core Blood Pressure
...... code SOΣ 1..1 code Coded responses from the common UCUM units for vital signs value set.
Fixed Value: mm[Hg]
ObligationsActor
SHALL:populate-if-known AU Core Responder from AU Core Blood Pressure
SHALL:no-error AU Core Requester from AU Core Blood Pressure
..... dataAbsentReason SOC 0..1 CodeableConcept Why the component result is missing
Binding: DataAbsentReason (extensible): Codes specifying why the result (Observation.value[x]) is missing.

ObligationsActor
SHALL:populate-if-known AU Core Responder from AU Core Blood Pressure
SHALL:no-error AU Core Requester from AU Core Blood Pressure
..... interpretation 0..* CodeableConcept High, low, normal, etc.
Binding: ObservationInterpretationCodes (extensible): Codes identifying interpretations of observations.


..... referenceRange 0..* See referenceRange (Observation) Provides guide for interpretation of component result
.... component:DiastolicBP SOΣC 1..1 BackboneElement Diastolic Blood Pressure
vs-3: If there is no a value a data absent reason must be present
ObligationsActor
SHALL:populate-if-known AU Core Responder from AU Core Blood Pressure
SHALL:no-error AU Core Requester from AU Core Blood Pressure
..... id 0..1 string Unique id for inter-element referencing
..... extension 0..* Extension Additional content defined by implementations
..... modifierExtension ?!Σ 0..* Extension Extensions that cannot be ignored even if unrecognized
..... code SOΣ 1..1 CodeableConcept Type of component observation (code / type)
Binding: VitalSigns (extensible): This identifies the vital sign result type.

ObligationsActor
SHALL:populate-if-known AU Core Responder from AU Core Blood Pressure
SHALL:no-error AU Core Requester from AU Core Blood Pressure
...... id 0..1 string Unique id for inter-element referencing
...... extension 0..* Extension Additional content defined by implementations
Slice: Unordered, Open by value:url
...... Slices for coding Σ 3..* Coding Diastolic Blood Pressure
Slice: Unordered, Open by value:code, value:system
....... coding:DBPCode Σ 1..1 Coding Diastolic Blood Pressure
........ id 0..1 string Unique id for inter-element referencing
........ extension 0..* Extension Additional content defined by implementations
Slice: Unordered, Open by value:url
........ system Σ 1..1 uri Identity of the terminology system
Fixed Value: http://loinc.org
........ version Σ 0..1 string Version of the system - if relevant
........ code Σ 1..1 code Symbol in syntax defined by the system
Fixed Value: 8462-4
........ display Σ 0..1 string Representation defined by the system
........ userSelected Σ 0..1 boolean If this coding was chosen directly by the user
....... coding:snomedDBP Σ 1..1 Coding SNOMED CT Diastolic Blood Pressure
........ id 0..1 string Unique id for inter-element referencing
........ extension 0..* Extension Additional content defined by implementations
Slice: Unordered, Open by value:url
........ system Σ 1..1 uri Identity of the terminology system
Fixed Value: http://snomed.info/sct
........ version Σ 0..1 string Version of the system - if relevant
........ code Σ 1..1 code Symbol in syntax defined by the system
Fixed Value: 271650006
........ display Σ 0..1 string Representation defined by the system
........ userSelected Σ 0..1 boolean If this coding was chosen directly by the user
....... coding:snomedSittingDBP SOΣ 1..1 Coding SNOMED CT Sitting Diastolic Blood Pressure
ObligationsActor
SHALL:populate-if-known Aus CVD Risk Calculator Launch Server
SHALL:process Aus CVD Risk Calculator Application
........ id 0..1 string Unique id for inter-element referencing
........ extension 0..* Extension Additional content defined by implementations
Slice: Unordered, Open by value:url
........ system SOΣ 1..1 uri Identity of the terminology system
Fixed Value: http://snomed.info/sct
ObligationsActor
SHALL:populate-if-known Aus CVD Risk Calculator Launch Server
SHALL:no-error Aus CVD Risk Calculator Application
........ version Σ 0..1 string Version of the system - if relevant
........ code SOΣ 1..1 code Symbol in syntax defined by the system
Fixed Value: 407555005
ObligationsActor
SHALL:populate-if-known Aus CVD Risk Calculator Launch Server
SHALL:no-error Aus CVD Risk Calculator Application
........ display Σ 0..1 string Representation defined by the system
........ userSelected Σ 0..1 boolean If this coding was chosen directly by the user
...... text Σ 0..1 string Plain text representation of the concept
..... value[x] SOΣC 0..1 Quantity Vital Sign Value recorded with UCUM
Binding: VitalSignsUnits (extensible): Common UCUM units for recording Vital Signs.

ObligationsActor
SHALL:populate-if-known AU Core Responder from AU Core Blood Pressure
SHALL:no-error AU Core Requester from AU Core Blood Pressure
...... id 0..1 string Unique id for inter-element referencing
...... extension 0..* Extension Additional content defined by implementations
Slice: Unordered, Open by value:url
...... value SOΣ 1..1 decimal Numerical value (with implicit precision)
ObligationsActor
SHALL:populate-if-known AU Core Responder from AU Core Blood Pressure
SHALL:no-error AU Core Requester from AU Core Blood Pressure
...... comparator ?!Σ 0..1 code < | <= | >= | > - how to understand the value
Binding: QuantityComparator (required): How the Quantity should be understood and represented.

...... unit SOΣ 1..1 string Unit representation
ObligationsActor
SHALL:populate-if-known AU Core Responder from AU Core Blood Pressure
SHALL:no-error AU Core Requester from AU Core Blood Pressure
...... system SOΣC 1..1 uri System that defines coded unit form
Fixed Value: http://unitsofmeasure.org
ObligationsActor
SHALL:populate-if-known AU Core Responder from AU Core Blood Pressure
SHALL:no-error AU Core Requester from AU Core Blood Pressure
...... code SOΣ 1..1 code Coded responses from the common UCUM units for vital signs value set.
Fixed Value: mm[Hg]
ObligationsActor
SHALL:populate-if-known AU Core Responder from AU Core Blood Pressure
SHALL:no-error AU Core Requester from AU Core Blood Pressure
..... dataAbsentReason SOC 0..1 CodeableConcept Why the component result is missing
Binding: DataAbsentReason (extensible): Codes specifying why the result (Observation.value[x]) is missing.

ObligationsActor
SHALL:populate-if-known AU Core Responder from AU Core Blood Pressure
SHALL:no-error AU Core Requester from AU Core Blood Pressure
..... interpretation 0..* CodeableConcept High, low, normal, etc.
Binding: ObservationInterpretationCodes (extensible): Codes identifying interpretations of observations.


..... referenceRange 0..* See referenceRange (Observation) Provides guide for interpretation of component result

doco Documentation for this format

Terminology Bindings

PathConformanceValueSet / CodeURI
Observation.languagepreferredCommonLanguages
http://hl7.org/fhir/ValueSet/languages
from the FHIR Standard
Additional Bindings Purpose
AllLanguages Max Binding
Observation.statusrequiredFixed Value: final
http://hl7.org/fhir/ValueSet/observation-status|4.0.1
from the FHIR Standard
Observation.categorypreferredObservationCategoryCodes
http://hl7.org/fhir/ValueSet/observation-category
from the FHIR Standard
Observation.category:VSCatpreferredObservationCategoryCodes
http://hl7.org/fhir/ValueSet/observation-category
from the FHIR Standard
Observation.codeextensibleVitalSigns
http://hl7.org/fhir/ValueSet/observation-vitalsignresult
from the FHIR Standard
Observation.dataAbsentReasonextensibleDataAbsentReason
http://hl7.org/fhir/ValueSet/data-absent-reason
from the FHIR Standard
Observation.interpretationextensibleObservationInterpretationCodes
http://hl7.org/fhir/ValueSet/observation-interpretation
from the FHIR Standard
Observation.bodySiteextensibleBodySite .
https://healthterminologies.gov.au/fhir/ValueSet/body-site-1
Observation.methodexampleObservationMethods
http://hl7.org/fhir/ValueSet/observation-methods
from the FHIR Standard
Observation.referenceRange.typepreferredObservationReferenceRangeMeaningCodes
http://hl7.org/fhir/ValueSet/referencerange-meaning
from the FHIR Standard
Observation.referenceRange.appliesToexampleObservationReferenceRangeAppliesToCodes
http://hl7.org/fhir/ValueSet/referencerange-appliesto
from the FHIR Standard
Observation.component.codeextensibleVitalSigns
http://hl7.org/fhir/ValueSet/observation-vitalsignresult
from the FHIR Standard
Observation.component.value[x]extensibleVitalSignsUnits
http://hl7.org/fhir/ValueSet/ucum-vitals-common|4.0.1
from the FHIR Standard
Observation.component.dataAbsentReasonextensibleDataAbsentReason
http://hl7.org/fhir/ValueSet/data-absent-reason
from the FHIR Standard
Observation.component.interpretationextensibleObservationInterpretationCodes
http://hl7.org/fhir/ValueSet/observation-interpretation
from the FHIR Standard
Observation.component:SystolicBP.codeextensibleVitalSigns
http://hl7.org/fhir/ValueSet/observation-vitalsignresult
from the FHIR Standard
Observation.component:SystolicBP.value[x]extensibleVitalSignsUnits
http://hl7.org/fhir/ValueSet/ucum-vitals-common|4.0.1
from the FHIR Standard
Observation.component:SystolicBP.value[x].comparatorrequiredQuantityComparator
http://hl7.org/fhir/ValueSet/quantity-comparator|4.0.1
from the FHIR Standard
Observation.component:SystolicBP.dataAbsentReasonextensibleDataAbsentReason
http://hl7.org/fhir/ValueSet/data-absent-reason
from the FHIR Standard
Observation.component:SystolicBP.interpretationextensibleObservationInterpretationCodes
http://hl7.org/fhir/ValueSet/observation-interpretation
from the FHIR Standard
Observation.component:DiastolicBP.codeextensibleVitalSigns
http://hl7.org/fhir/ValueSet/observation-vitalsignresult
from the FHIR Standard
Observation.component:DiastolicBP.value[x]extensibleVitalSignsUnits
http://hl7.org/fhir/ValueSet/ucum-vitals-common|4.0.1
from the FHIR Standard
Observation.component:DiastolicBP.value[x].comparatorrequiredQuantityComparator
http://hl7.org/fhir/ValueSet/quantity-comparator|4.0.1
from the FHIR Standard
Observation.component:DiastolicBP.dataAbsentReasonextensibleDataAbsentReason
http://hl7.org/fhir/ValueSet/data-absent-reason
from the FHIR Standard
Observation.component:DiastolicBP.interpretationextensibleObservationInterpretationCodes
http://hl7.org/fhir/ValueSet/observation-interpretation
from the FHIR Standard

Constraints

IdGradePath(s)DetailsRequirements
au-core-obs-01errorObservation.bodySiteIf a coded body site is provided, at least one coding shall be from SNOMED CT
: coding.exists() implies coding.where(system='http://snomed.info/sct').exists()
dom-2errorObservationIf the resource is contained in another resource, it SHALL NOT contain nested Resources
: contained.contained.empty()
dom-3errorObservationIf the resource is contained in another resource, it SHALL be referred to from elsewhere in the resource or SHALL refer to the containing resource
: contained.where((('#'+id in (%resource.descendants().reference | %resource.descendants().as(canonical) | %resource.descendants().as(uri) | %resource.descendants().as(url))) or descendants().where(reference = '#').exists() or descendants().where(as(canonical) = '#').exists() or descendants().where(as(canonical) = '#').exists()).not()).trace('unmatched', id).empty()
dom-4errorObservationIf a resource is contained in another resource, it SHALL NOT have a meta.versionId or a meta.lastUpdated
: contained.meta.versionId.empty() and contained.meta.lastUpdated.empty()
dom-5errorObservationIf a resource is contained in another resource, it SHALL NOT have a security label
: contained.meta.security.empty()
dom-6best practiceObservationA resource should have narrative for robust management
: text.`div`.exists()
ele-1error**ALL** elementsAll FHIR elements must have a @value or children
: hasValue() or (children().count() > id.count())
ext-1error**ALL** extensionsMust have either extensions or value[x], not both
: extension.exists() != value.exists()
obs-3errorObservation.referenceRangeMust have at least a low or a high or text
: low.exists() or high.exists() or text.exists()
obs-6errorObservationdataAbsentReason SHALL only be present if Observation.value[x] is not present
: dataAbsentReason.empty() or value.empty()
obs-7errorObservationIf Observation.code is the same as an Observation.component.code then the value element associated with the code SHALL NOT be present
: value.empty() or component.code.where(coding.intersect(%resource.code.coding).exists()).empty()
vs-1errorObservation.effective[x]if Observation.effective[x] is dateTime and has a value then that value shall be precise to the day
: $this is dateTime implies $this.toString().length() >= 10
vs-2errorObservationIf there is no component or hasMember element then either a value[x] or a data absent reason must be present.
: (component.empty() and hasMember.empty()) implies (dataAbsentReason.exists() or value.exists())
vs-3errorObservation.component, Observation.component:SystolicBP, Observation.component:DiastolicBPIf there is no a value a data absent reason must be present
: value.exists() or dataAbsentReason.exists()

This structure is derived from AUCoreBloodPressure

Summary

Mandatory: 9 elements
Must-Support: 9 elements
Fixed: 7 elements

Key Elements View

NameFlagsCard.TypeDescription & Constraintsdoco
.. Observation C 0..* AUCoreBloodPressure Sitting blood pressure result
dom-2: If the resource is contained in another resource, it SHALL NOT contain nested Resources
dom-3: If the resource is contained in another resource, it SHALL be referred to from elsewhere in the resource or SHALL refer to the containing resource
dom-4: If a resource is contained in another resource, it SHALL NOT have a meta.versionId or a meta.lastUpdated
dom-5: If a resource is contained in another resource, it SHALL NOT have a security label
dom-6: A resource should have narrative for robust management
obs-6: dataAbsentReason SHALL only be present if Observation.value[x] is not present
obs-7: If Observation.code is the same as an Observation.component.code then the value element associated with the code SHALL NOT be present
vs-2: If there is no component or hasMember element then either a value[x] or a data absent reason must be present.
... implicitRules ?!Σ 0..1 uri A set of rules under which this content was created
ele-1: All FHIR elements must have a @value or children
... modifierExtension ?! 0..* Extension Extensions that cannot be ignored
ele-1: All FHIR elements must have a @value or children
ext-1: Must have either extensions or value[x], not both
... status ?!SOΣ 1..1 code registered | preliminary | final | amended +
Binding: ObservationStatus (required)
ele-1: All FHIR elements must have a @value or children
Fixed Value: final
ObligationsActor
SHALL:populate-if-known AU Core Responder from AU Core Blood Pressure
SHALL:no-error AU Core Requester from AU Core Blood Pressure
SHALL:populate-if-known & SHALL:process AU Core ResponderAus CVD Risk Calculator Application
SHALL:no-error AU Core Requester
.... category:VSCat SO 1..1 CodeableConcept Classification of type of observation
Binding: ObservationCategoryCodes (preferred): Codes for high level observation categories.


ele-1: All FHIR elements must have a @value or children
ObligationsActor
SHALL:populate-if-known AU Core Responder from AU Core Blood Pressure
SHALL:no-error AU Core Requester from AU Core Blood Pressure
..... coding SOΣ 1..* Coding Code defined by a terminology system
ele-1: All FHIR elements must have a @value or children
ObligationsActor
SHALL:populate-if-known AU Core Responder from AU Core Blood Pressure
SHALL:no-error AU Core Requester from AU Core Blood Pressure
...... system SOΣ 1..1 uri Identity of the terminology system
ele-1: All FHIR elements must have a @value or children
Fixed Value: http://terminology.hl7.org/CodeSystem/observation-category
ObligationsActor
SHALL:populate-if-known AU Core Responder from AU Core Blood Pressure
SHALL:no-error AU Core Requester from AU Core Blood Pressure
...... code SOΣ 1..1 code Symbol in syntax defined by the system
ele-1: All FHIR elements must have a @value or children
Fixed Value: vital-signs
ObligationsActor
SHALL:populate-if-known AU Core Responder from AU Core Blood Pressure
SHALL:no-error AU Core Requester from AU Core Blood Pressure
... code SOΣ 1..1 CodeableConcept Blood Pressure
Binding: VitalSigns (extensible): This identifies the vital sign result type.


ele-1: All FHIR elements must have a @value or children
ObligationsActor
SHALL:populate-if-known AU Core Responder from AU Core Blood Pressure
SHALL:no-error AU Core Requester from AU Core Blood Pressure
SHALL:populate-if-known & SHALL:process AU Core ResponderAus CVD Risk Calculator Application
SHALL:no-error AU Core Requester
.... Slices for coding Σ 3..* Coding Code defined by a terminology system
Slice: Unordered, Open by value:code, value:system
ele-1: All FHIR elements must have a @value or children
..... coding:BPCode Σ 1..1 Coding Code defined by a terminology system
ele-1: All FHIR elements must have a @value or children
...... system Σ 1..1 uri Identity of the terminology system
ele-1: All FHIR elements must have a @value or children
Fixed Value: http://loinc.org
...... code Σ 1..1 code Symbol in syntax defined by the system
ele-1: All FHIR elements must have a @value or children
Fixed Value: 85354-9
..... coding:snomedBPCode Σ 1..1 Coding SNOMED CT Blood Pressure
ele-1: All FHIR elements must have a @value or children
...... system Σ 1..1 uri Identity of the terminology system
ele-1: All FHIR elements must have a @value or children
Fixed Value: http://snomed.info/sct
...... code Σ 1..1 code Symbol in syntax defined by the system
ele-1: All FHIR elements must have a @value or children
Fixed Value: 75367002
..... coding:snomedSittingBPCode SOΣ 1..1 Coding SNOMED CT Sitting Blood Pressure
ele-1: All FHIR elements must have a @value or children
ObligationsActor
SHALL:populate-if-known Aus CVD Risk Calculator Launch Server
SHALL:process Aus CVD Risk Calculator Application
...... system SOΣ 1..1 uri Identity of the terminology system
ele-1: All FHIR elements must have a @value or children
Fixed Value: http://snomed.info/sct
ObligationsActor
SHALL:populate-if-known Aus CVD Risk Calculator Launch Server
SHALL:process Aus CVD Risk Calculator Application
...... code SOΣ 1..1 code Symbol in syntax defined by the system
ele-1: All FHIR elements must have a @value or children
Fixed Value: 163035008
ObligationsActor
SHALL:populate-if-known Aus CVD Risk Calculator Launch Server
SHALL:process Aus CVD Risk Calculator Application
... subject SOΣ 1..1 Reference(AU Core Patient) Who and/or what the observation is about
ele-1: All FHIR elements must have a @value or children
ObligationsActor
SHALL:populate-if-known AU Core Responder from AU Core Blood Pressure
SHALL:no-error AU Core Requester from AU Core Blood Pressure
SHALL:populate-if-known & SHALL:process AU Core ResponderAus CVD Risk Calculator Application
SHALL:no-error AU Core Requester
... effective[x] SOΣC 1..1 dateTime Date, and optionally time, the observation was performed
ele-1: All FHIR elements must have a @value or children
vs-1: if Observation.effective[x] is dateTime and has a value then that value shall be precise to the day
ObligationsActor
SHALL:populate-if-known AU Core Responder from AU Core Blood Pressure
SHALL:no-error AU Core Requester from AU Core Blood Pressure
... Slices for value[x] SΣC 0..1 Quantity Vital Signs value are recorded using the Quantity data type. For supporting observations such as Cuff size could use other datatypes such as CodeableConcept.
Slice: Unordered, Closed by type:$this
ele-1: All FHIR elements must have a @value or children
... dataAbsentReason SOC 0..1 CodeableConcept Why the result is missing
Binding: DataAbsentReason (extensible): Codes specifying why the result (Observation.value[x]) is missing.


ele-1: All FHIR elements must have a @value or children
ObligationsActor
SHALL:populate-if-known AU Core Responder from AU Core Blood Pressure
SHALL:no-error AU Core Requester from AU Core Blood Pressure
... Slices for component SOΣC 2..* BackboneElement Used when reporting systolic and diastolic blood pressure.
Slice: Unordered, Open by value:code.coding.code, value:code.coding.system
ele-1: All FHIR elements must have a @value or children
vs-3: If there is no a value a data absent reason must be present
ObligationsActor
SHALL:populate-if-known AU Core Responder from AU Core Blood Pressure
SHALL:no-error AU Core Requester from AU Core Blood Pressure
SHALL:populate-if-known & SHALL:process AU Core ResponderAus CVD Risk Calculator Application
SHALL:no-error AU Core Requester
.... component:All Slices Content/Rules for all slices
..... modifierExtension ?!Σ 0..* Extension Extensions that cannot be ignored even if unrecognized
ele-1: All FHIR elements must have a @value or children
ext-1: Must have either extensions or value[x], not both
..... code SOΣ 1..1 CodeableConcept Type of component observation (code / type)
Binding: VitalSigns (extensible): This identifies the vital sign result type.


ele-1: All FHIR elements must have a @value or children
ObligationsActor
SHALL:populate-if-known AU Core Responder from AU Core Blood Pressure
SHALL:no-error AU Core Requester from AU Core Blood Pressure
..... value[x] SOΣC 0..1 Vital Sign Value recorded with UCUM
Binding: VitalSignsUnits (extensible): Common UCUM units for recording Vital Signs.


ele-1: All FHIR elements must have a @value or children
ObligationsActor
SHALL:populate-if-known AU Core Responder from AU Core Blood Pressure
SHALL:no-error AU Core Requester from AU Core Blood Pressure
...... valueQuantity Quantity
...... valueCodeableConcept CodeableConcept
...... valueString string
...... valueBoolean boolean
...... valueInteger integer
...... valueRange Range
...... valueRatio Ratio
...... valueSampledData SampledData
...... valueTime time
...... valueDateTime dateTime
...... valuePeriod Period
..... dataAbsentReason SOC 0..1 CodeableConcept Why the component result is missing
Binding: DataAbsentReason (extensible): Codes specifying why the result (Observation.value[x]) is missing.


ele-1: All FHIR elements must have a @value or children
ObligationsActor
SHALL:populate-if-known AU Core Responder from AU Core Blood Pressure
SHALL:no-error AU Core Requester from AU Core Blood Pressure
.... component:SystolicBP SOΣC 1..1 BackboneElement Systolic Blood Pressure
ele-1: All FHIR elements must have a @value or children
vs-3: If there is no a value a data absent reason must be present
ObligationsActor
SHALL:populate-if-known AU Core Responder from AU Core Blood Pressure
SHALL:no-error AU Core Requester from AU Core Blood Pressure
..... modifierExtension ?!Σ 0..* Extension Extensions that cannot be ignored even if unrecognized
ele-1: All FHIR elements must have a @value or children
ext-1: Must have either extensions or value[x], not both
..... code SOΣ 1..1 CodeableConcept Type of component observation (code / type)
Binding: VitalSigns (extensible): This identifies the vital sign result type.


ele-1: All FHIR elements must have a @value or children
ObligationsActor
SHALL:populate-if-known AU Core Responder from AU Core Blood Pressure
SHALL:no-error AU Core Requester from AU Core Blood Pressure
...... Slices for coding Σ 3..* Coding Systolic Blood Pressure
Slice: Unordered, Open by value:code, value:system
ele-1: All FHIR elements must have a @value or children
....... coding:SBPCode Σ 1..1 Coding Systolic Blood Pressure
ele-1: All FHIR elements must have a @value or children
........ system Σ 1..1 uri Identity of the terminology system
ele-1: All FHIR elements must have a @value or children
Fixed Value: http://loinc.org
........ code Σ 1..1 code Symbol in syntax defined by the system
ele-1: All FHIR elements must have a @value or children
Fixed Value: 8480-6
....... coding:snomedSBP Σ 1..1 Coding SNOMED CT Systolic Blood Pressure
ele-1: All FHIR elements must have a @value or children
........ system Σ 1..1 uri Identity of the terminology system
ele-1: All FHIR elements must have a @value or children
Fixed Value: http://snomed.info/sct
........ code Σ 1..1 code Symbol in syntax defined by the system
ele-1: All FHIR elements must have a @value or children
Fixed Value: 271649006
....... coding:snomedSittingSBP SOΣ 1..1 Coding SNOMED CT Sitting Systolic Blood Pressure
ele-1: All FHIR elements must have a @value or children
ObligationsActor
SHALL:populate-if-known Aus CVD Risk Calculator Launch Server
SHALL:process Aus CVD Risk Calculator Application
........ system SOΣ 1..1 uri Identity of the terminology system
ele-1: All FHIR elements must have a @value or children
Fixed Value: http://snomed.info/sct
ObligationsActor
SHALL:populate-if-known Aus CVD Risk Calculator Launch Server
SHALL:process Aus CVD Risk Calculator Application
........ code SOΣ 1..1 code Symbol in syntax defined by the system
ele-1: All FHIR elements must have a @value or children
Fixed Value: 407554009
ObligationsActor
SHALL:populate-if-known Aus CVD Risk Calculator Launch Server
SHALL:process Aus CVD Risk Calculator Application
..... value[x] SOΣC 0..1 Quantity Vital Sign Value recorded with UCUM
Binding: VitalSignsUnits (extensible): Common UCUM units for recording Vital Signs.


ele-1: All FHIR elements must have a @value or children
ObligationsActor
SHALL:populate-if-known AU Core Responder from AU Core Blood Pressure
SHALL:no-error AU Core Requester from AU Core Blood Pressure
...... value SOΣ 1..1 decimal Numerical value (with implicit precision)
ele-1: All FHIR elements must have a @value or children
ObligationsActor
SHALL:populate-if-known AU Core Responder from AU Core Blood Pressure
SHALL:no-error AU Core Requester from AU Core Blood Pressure
...... comparator ?!Σ 0..1 code < | <= | >= | > - how to understand the value
Binding: QuantityComparator (required): How the Quantity should be understood and represented.


ele-1: All FHIR elements must have a @value or children
...... unit SOΣ 1..1 string Unit representation
ele-1: All FHIR elements must have a @value or children
ObligationsActor
SHALL:populate-if-known AU Core Responder from AU Core Blood Pressure
SHALL:no-error AU Core Requester from AU Core Blood Pressure
...... system SOΣC 1..1 uri System that defines coded unit form
ele-1: All FHIR elements must have a @value or children
Fixed Value: http://unitsofmeasure.org
ObligationsActor
SHALL:populate-if-known AU Core Responder from AU Core Blood Pressure
SHALL:no-error AU Core Requester from AU Core Blood Pressure
...... code SOΣ 1..1 code Coded responses from the common UCUM units for vital signs value set.
ele-1: All FHIR elements must have a @value or children
Fixed Value: mm[Hg]
ObligationsActor
SHALL:populate-if-known AU Core Responder from AU Core Blood Pressure
SHALL:no-error AU Core Requester from AU Core Blood Pressure
..... dataAbsentReason SOC 0..1 CodeableConcept Why the component result is missing
Binding: DataAbsentReason (extensible): Codes specifying why the result (Observation.value[x]) is missing.


ele-1: All FHIR elements must have a @value or children
ObligationsActor
SHALL:populate-if-known AU Core Responder from AU Core Blood Pressure
SHALL:no-error AU Core Requester from AU Core Blood Pressure
.... component:DiastolicBP SOΣC 1..1 BackboneElement Diastolic Blood Pressure
ele-1: All FHIR elements must have a @value or children
vs-3: If there is no a value a data absent reason must be present
ObligationsActor
SHALL:populate-if-known AU Core Responder from AU Core Blood Pressure
SHALL:no-error AU Core Requester from AU Core Blood Pressure
..... modifierExtension ?!Σ 0..* Extension Extensions that cannot be ignored even if unrecognized
ele-1: All FHIR elements must have a @value or children
ext-1: Must have either extensions or value[x], not both
..... code SOΣ 1..1 CodeableConcept Type of component observation (code / type)
Binding: VitalSigns (extensible): This identifies the vital sign result type.


ele-1: All FHIR elements must have a @value or children
ObligationsActor
SHALL:populate-if-known AU Core Responder from AU Core Blood Pressure
SHALL:no-error AU Core Requester from AU Core Blood Pressure
...... Slices for coding Σ 3..* Coding Diastolic Blood Pressure
Slice: Unordered, Open by value:code, value:system
ele-1: All FHIR elements must have a @value or children
....... coding:DBPCode Σ 1..1 Coding Diastolic Blood Pressure
ele-1: All FHIR elements must have a @value or children
........ system Σ 1..1 uri Identity of the terminology system
ele-1: All FHIR elements must have a @value or children
Fixed Value: http://loinc.org
........ code Σ 1..1 code Symbol in syntax defined by the system
ele-1: All FHIR elements must have a @value or children
Fixed Value: 8462-4
....... coding:snomedDBP Σ 1..1 Coding SNOMED CT Diastolic Blood Pressure
ele-1: All FHIR elements must have a @value or children
........ system Σ 1..1 uri Identity of the terminology system
ele-1: All FHIR elements must have a @value or children
Fixed Value: http://snomed.info/sct
........ code Σ 1..1 code Symbol in syntax defined by the system
ele-1: All FHIR elements must have a @value or children
Fixed Value: 271650006
....... coding:snomedSittingDBP SOΣ 1..1 Coding SNOMED CT Sitting Diastolic Blood Pressure
ele-1: All FHIR elements must have a @value or children
ObligationsActor
SHALL:populate-if-known Aus CVD Risk Calculator Launch Server
SHALL:process Aus CVD Risk Calculator Application
........ system SOΣ 1..1 uri Identity of the terminology system
ele-1: All FHIR elements must have a @value or children
Fixed Value: http://snomed.info/sct
ObligationsActor
SHALL:populate-if-known Aus CVD Risk Calculator Launch Server
SHALL:no-error Aus CVD Risk Calculator Application
........ code SOΣ 1..1 code Symbol in syntax defined by the system
ele-1: All FHIR elements must have a @value or children
Fixed Value: 407555005
ObligationsActor
SHALL:populate-if-known Aus CVD Risk Calculator Launch Server
SHALL:no-error Aus CVD Risk Calculator Application
..... value[x] SOΣC 0..1 Quantity Vital Sign Value recorded with UCUM
Binding: VitalSignsUnits (extensible): Common UCUM units for recording Vital Signs.


ele-1: All FHIR elements must have a @value or children
ObligationsActor
SHALL:populate-if-known AU Core Responder from AU Core Blood Pressure
SHALL:no-error AU Core Requester from AU Core Blood Pressure
...... value SOΣ 1..1 decimal Numerical value (with implicit precision)
ele-1: All FHIR elements must have a @value or children
ObligationsActor
SHALL:populate-if-known AU Core Responder from AU Core Blood Pressure
SHALL:no-error AU Core Requester from AU Core Blood Pressure
...... comparator ?!Σ 0..1 code < | <= | >= | > - how to understand the value
Binding: QuantityComparator (required): How the Quantity should be understood and represented.


ele-1: All FHIR elements must have a @value or children
...... unit SOΣ 1..1 string Unit representation
ele-1: All FHIR elements must have a @value or children
ObligationsActor
SHALL:populate-if-known AU Core Responder from AU Core Blood Pressure
SHALL:no-error AU Core Requester from AU Core Blood Pressure
...... system SOΣC 1..1 uri System that defines coded unit form
ele-1: All FHIR elements must have a @value or children
Fixed Value: http://unitsofmeasure.org
ObligationsActor
SHALL:populate-if-known AU Core Responder from AU Core Blood Pressure
SHALL:no-error AU Core Requester from AU Core Blood Pressure
...... code SOΣ 1..1 code Coded responses from the common UCUM units for vital signs value set.
ele-1: All FHIR elements must have a @value or children
Fixed Value: mm[Hg]
ObligationsActor
SHALL:populate-if-known AU Core Responder from AU Core Blood Pressure
SHALL:no-error AU Core Requester from AU Core Blood Pressure
..... dataAbsentReason SOC 0..1 CodeableConcept Why the component result is missing
Binding: DataAbsentReason (extensible): Codes specifying why the result (Observation.value[x]) is missing.


ele-1: All FHIR elements must have a @value or children
ObligationsActor
SHALL:populate-if-known AU Core Responder from AU Core Blood Pressure
SHALL:no-error AU Core Requester from AU Core Blood Pressure

doco Documentation for this format

Terminology Bindings

PathConformanceValueSet / CodeURI
Observation.statusrequiredFixed Value: final
http://hl7.org/fhir/ValueSet/observation-status|4.0.1
from the FHIR Standard
Observation.categorypreferredObservationCategoryCodes
http://hl7.org/fhir/ValueSet/observation-category
from the FHIR Standard
Observation.category:VSCatpreferredObservationCategoryCodes
http://hl7.org/fhir/ValueSet/observation-category
from the FHIR Standard
Observation.codeextensibleVitalSigns
http://hl7.org/fhir/ValueSet/observation-vitalsignresult
from the FHIR Standard
Observation.dataAbsentReasonextensibleDataAbsentReason
http://hl7.org/fhir/ValueSet/data-absent-reason
from the FHIR Standard
Observation.component.codeextensibleVitalSigns
http://hl7.org/fhir/ValueSet/observation-vitalsignresult
from the FHIR Standard
Observation.component.value[x]extensibleVitalSignsUnits
http://hl7.org/fhir/ValueSet/ucum-vitals-common|4.0.1
from the FHIR Standard
Observation.component.dataAbsentReasonextensibleDataAbsentReason
http://hl7.org/fhir/ValueSet/data-absent-reason
from the FHIR Standard
Observation.component:SystolicBP.codeextensibleVitalSigns
http://hl7.org/fhir/ValueSet/observation-vitalsignresult
from the FHIR Standard
Observation.component:SystolicBP.value[x]extensibleVitalSignsUnits
http://hl7.org/fhir/ValueSet/ucum-vitals-common|4.0.1
from the FHIR Standard
Observation.component:SystolicBP.value[x].comparatorrequiredQuantityComparator
http://hl7.org/fhir/ValueSet/quantity-comparator|4.0.1
from the FHIR Standard
Observation.component:SystolicBP.dataAbsentReasonextensibleDataAbsentReason
http://hl7.org/fhir/ValueSet/data-absent-reason
from the FHIR Standard
Observation.component:DiastolicBP.codeextensibleVitalSigns
http://hl7.org/fhir/ValueSet/observation-vitalsignresult
from the FHIR Standard
Observation.component:DiastolicBP.value[x]extensibleVitalSignsUnits
http://hl7.org/fhir/ValueSet/ucum-vitals-common|4.0.1
from the FHIR Standard
Observation.component:DiastolicBP.value[x].comparatorrequiredQuantityComparator
http://hl7.org/fhir/ValueSet/quantity-comparator|4.0.1
from the FHIR Standard
Observation.component:DiastolicBP.dataAbsentReasonextensibleDataAbsentReason
http://hl7.org/fhir/ValueSet/data-absent-reason
from the FHIR Standard

Constraints

IdGradePath(s)DetailsRequirements
dom-2errorObservationIf the resource is contained in another resource, it SHALL NOT contain nested Resources
: contained.contained.empty()
dom-3errorObservationIf the resource is contained in another resource, it SHALL be referred to from elsewhere in the resource or SHALL refer to the containing resource
: contained.where((('#'+id in (%resource.descendants().reference | %resource.descendants().as(canonical) | %resource.descendants().as(uri) | %resource.descendants().as(url))) or descendants().where(reference = '#').exists() or descendants().where(as(canonical) = '#').exists() or descendants().where(as(canonical) = '#').exists()).not()).trace('unmatched', id).empty()
dom-4errorObservationIf a resource is contained in another resource, it SHALL NOT have a meta.versionId or a meta.lastUpdated
: contained.meta.versionId.empty() and contained.meta.lastUpdated.empty()
dom-5errorObservationIf a resource is contained in another resource, it SHALL NOT have a security label
: contained.meta.security.empty()
dom-6best practiceObservationA resource should have narrative for robust management
: text.`div`.exists()
ele-1error**ALL** elementsAll FHIR elements must have a @value or children
: hasValue() or (children().count() > id.count())
ext-1error**ALL** extensionsMust have either extensions or value[x], not both
: extension.exists() != value.exists()
obs-6errorObservationdataAbsentReason SHALL only be present if Observation.value[x] is not present
: dataAbsentReason.empty() or value.empty()
obs-7errorObservationIf Observation.code is the same as an Observation.component.code then the value element associated with the code SHALL NOT be present
: value.empty() or component.code.where(coding.intersect(%resource.code.coding).exists()).empty()
vs-1errorObservation.effective[x]if Observation.effective[x] is dateTime and has a value then that value shall be precise to the day
: $this is dateTime implies $this.toString().length() >= 10
vs-2errorObservationIf there is no component or hasMember element then either a value[x] or a data absent reason must be present.
: (component.empty() and hasMember.empty()) implies (dataAbsentReason.exists() or value.exists())
vs-3errorObservation.component, Observation.component:SystolicBP, Observation.component:DiastolicBPIf there is no a value a data absent reason must be present
: value.exists() or dataAbsentReason.exists()

Differential View

This structure is derived from AUCoreBloodPressure

NameFlagsCard.TypeDescription & Constraintsdoco
.. Observation 0..* AUCoreBloodPressure Sitting blood pressure result
... status O 1..1 code registered | preliminary | final | amended +
Fixed Value: final
ObligationsActor
SHALL:populate-if-known & SHALL:process AU Core ResponderAus CVD Risk Calculator Application
SHALL:no-error AU Core Requester
... code O 1..1 CodeableConcept Blood Pressure
ObligationsActor
SHALL:populate-if-known & SHALL:process AU Core ResponderAus CVD Risk Calculator Application
SHALL:no-error AU Core Requester
.... coding 3..* Coding Code defined by a terminology system
.... Slices for coding Content/Rules for all slices
..... coding:snomedSittingBPCode SO 1..1 Coding SNOMED CT Sitting Blood Pressure
ObligationsActor
SHALL:populate-if-known Aus CVD Risk Calculator Launch Server
SHALL:process Aus CVD Risk Calculator Application
...... system SO 1..1 uri Identity of the terminology system
Fixed Value: http://snomed.info/sct
ObligationsActor
SHALL:populate-if-known Aus CVD Risk Calculator Launch Server
SHALL:process Aus CVD Risk Calculator Application
...... code SO 1..1 code Symbol in syntax defined by the system
Fixed Value: 163035008
ObligationsActor
SHALL:populate-if-known Aus CVD Risk Calculator Launch Server
SHALL:process Aus CVD Risk Calculator Application
... subject O 1..1 Reference(AU Core Patient) Who and/or what the observation is about
ObligationsActor
SHALL:populate-if-known & SHALL:process AU Core ResponderAus CVD Risk Calculator Application
SHALL:no-error AU Core Requester
... Slices for component Content/Rules for all slices
.... component:SystolicBP 1..1 BackboneElement Systolic Blood Pressure
..... code
...... coding 3..* Coding Systolic Blood Pressure
...... Slices for coding Content/Rules for all slices
....... coding:snomedSittingSBP SO 1..1 Coding SNOMED CT Sitting Systolic Blood Pressure
ObligationsActor
SHALL:populate-if-known Aus CVD Risk Calculator Launch Server
SHALL:process Aus CVD Risk Calculator Application
........ system SO 1..1 uri Identity of the terminology system
Fixed Value: http://snomed.info/sct
ObligationsActor
SHALL:populate-if-known Aus CVD Risk Calculator Launch Server
SHALL:process Aus CVD Risk Calculator Application
........ code SO 1..1 code Symbol in syntax defined by the system
Fixed Value: 407554009
ObligationsActor
SHALL:populate-if-known Aus CVD Risk Calculator Launch Server
SHALL:process Aus CVD Risk Calculator Application
.... component:DiastolicBP 1..1 BackboneElement Diastolic Blood Pressure
..... code
...... coding 3..* Coding Diastolic Blood Pressure
...... Slices for coding Content/Rules for all slices
....... coding:snomedSittingDBP SO 1..1 Coding SNOMED CT Sitting Diastolic Blood Pressure
ObligationsActor
SHALL:populate-if-known Aus CVD Risk Calculator Launch Server
SHALL:process Aus CVD Risk Calculator Application
........ system SO 1..1 uri Identity of the terminology system
Fixed Value: http://snomed.info/sct
ObligationsActor
SHALL:populate-if-known Aus CVD Risk Calculator Launch Server
SHALL:no-error Aus CVD Risk Calculator Application
........ code SO 1..1 code Symbol in syntax defined by the system
Fixed Value: 407555005
ObligationsActor
SHALL:populate-if-known Aus CVD Risk Calculator Launch Server
SHALL:no-error Aus CVD Risk Calculator Application

doco Documentation for this format

Snapshot View

NameFlagsCard.TypeDescription & Constraintsdoco
.. Observation C 0..* AUCoreBloodPressure Sitting blood pressure result
obs-6: dataAbsentReason SHALL only be present if Observation.value[x] is not present
obs-7: If Observation.code is the same as an Observation.component.code then the value element associated with the code SHALL NOT be present
vs-2: If there is no component or hasMember element then either a value[x] or a data absent reason must be present.
... id Σ 0..1 id Logical id of this artifact
... meta Σ 0..1 Meta Metadata about the resource
... implicitRules ?!Σ 0..1 uri A set of rules under which this content was created
... language 0..1 code Language of the resource content
Binding: CommonLanguages (preferred): A human language.

Additional BindingsPurpose
AllLanguages Max Binding
... text 0..1 Narrative Text summary of the resource, for human interpretation
... contained 0..* Resource Contained, inline Resources
... extension 0..* Extension Additional content defined by implementations
... modifierExtension ?! 0..* Extension Extensions that cannot be ignored
... identifier Σ 0..* Identifier Business Identifier for observation
... basedOn Σ 0..* Reference(CarePlan | DeviceRequest | ImmunizationRecommendation | MedicationRequest | NutritionOrder | ServiceRequest) Fulfills plan, proposal or order
... partOf Σ 0..* Reference(MedicationAdministration | MedicationDispense | MedicationStatement | Procedure | Immunization | ImagingStudy) Part of referenced event
... status ?!SOΣ 1..1 code registered | preliminary | final | amended +
Binding: ObservationStatus (required)
Fixed Value: final
ObligationsActor
SHALL:populate-if-known AU Core Responder from AU Core Blood Pressure
SHALL:no-error AU Core Requester from AU Core Blood Pressure
SHALL:populate-if-known & SHALL:process AU Core ResponderAus CVD Risk Calculator Application
SHALL:no-error AU Core Requester
... Slices for category SO 1..* CodeableConcept Classification of type of observation
Slice: Unordered, Open by value:coding.code, value:coding.system
Binding: ObservationCategoryCodes (preferred): Codes for high level observation categories.


ObligationsActor
SHALL:populate-if-known AU Core Responder from AU Core Blood Pressure
SHALL:no-error AU Core Requester from AU Core Blood Pressure
.... category:VSCat SO 1..1 CodeableConcept Classification of type of observation
Binding: ObservationCategoryCodes (preferred): Codes for high level observation categories.


ObligationsActor
SHALL:populate-if-known AU Core Responder from AU Core Blood Pressure
SHALL:no-error AU Core Requester from AU Core Blood Pressure
..... id 0..1 string Unique id for inter-element referencing
..... extension 0..* Extension Additional content defined by implementations
Slice: Unordered, Open by value:url
..... coding SOΣ 1..* Coding Code defined by a terminology system
ObligationsActor
SHALL:populate-if-known AU Core Responder from AU Core Blood Pressure
SHALL:no-error AU Core Requester from AU Core Blood Pressure
...... id 0..1 string Unique id for inter-element referencing
...... extension 0..* Extension Additional content defined by implementations
Slice: Unordered, Open by value:url
...... system SOΣ 1..1 uri Identity of the terminology system
Fixed Value: http://terminology.hl7.org/CodeSystem/observation-category
ObligationsActor
SHALL:populate-if-known AU Core Responder from AU Core Blood Pressure
SHALL:no-error AU Core Requester from AU Core Blood Pressure
...... version Σ 0..1 string Version of the system - if relevant
...... code SOΣ 1..1 code Symbol in syntax defined by the system
Fixed Value: vital-signs
ObligationsActor
SHALL:populate-if-known AU Core Responder from AU Core Blood Pressure
SHALL:no-error AU Core Requester from AU Core Blood Pressure
...... display Σ 0..1 string Representation defined by the system
...... userSelected Σ 0..1 boolean If this coding was chosen directly by the user
..... text Σ 0..1 string Plain text representation of the concept
... code SOΣ 1..1 CodeableConcept Blood Pressure
Binding: VitalSigns (extensible): This identifies the vital sign result type.

ObligationsActor
SHALL:populate-if-known AU Core Responder from AU Core Blood Pressure
SHALL:no-error AU Core Requester from AU Core Blood Pressure
SHALL:populate-if-known & SHALL:process AU Core ResponderAus CVD Risk Calculator Application
SHALL:no-error AU Core Requester
.... id 0..1 string Unique id for inter-element referencing
.... extension 0..* Extension Additional content defined by implementations
Slice: Unordered, Open by value:url
.... Slices for coding Σ 3..* Coding Code defined by a terminology system
Slice: Unordered, Open by value:code, value:system
..... coding:BPCode Σ 1..1 Coding Code defined by a terminology system
...... id 0..1 string Unique id for inter-element referencing
...... extension 0..* Extension Additional content defined by implementations
Slice: Unordered, Open by value:url
...... system Σ 1..1 uri Identity of the terminology system
Fixed Value: http://loinc.org
...... version Σ 0..1 string Version of the system - if relevant
...... code Σ 1..1 code Symbol in syntax defined by the system
Fixed Value: 85354-9
...... display Σ 0..1 string Representation defined by the system
...... userSelected Σ 0..1 boolean If this coding was chosen directly by the user
..... coding:snomedBPCode Σ 1..1 Coding SNOMED CT Blood Pressure
...... id 0..1 string Unique id for inter-element referencing
...... extension 0..* Extension Additional content defined by implementations
Slice: Unordered, Open by value:url
...... system Σ 1..1 uri Identity of the terminology system
Fixed Value: http://snomed.info/sct
...... version Σ 0..1 string Version of the system - if relevant
...... code Σ 1..1 code Symbol in syntax defined by the system
Fixed Value: 75367002
...... display Σ 0..1 string Representation defined by the system
...... userSelected Σ 0..1 boolean If this coding was chosen directly by the user
..... coding:snomedSittingBPCode SOΣ 1..1 Coding SNOMED CT Sitting Blood Pressure
ObligationsActor
SHALL:populate-if-known Aus CVD Risk Calculator Launch Server
SHALL:process Aus CVD Risk Calculator Application
...... id 0..1 string Unique id for inter-element referencing
...... extension 0..* Extension Additional content defined by implementations
Slice: Unordered, Open by value:url
...... system SOΣ 1..1 uri Identity of the terminology system
Fixed Value: http://snomed.info/sct
ObligationsActor
SHALL:populate-if-known Aus CVD Risk Calculator Launch Server
SHALL:process Aus CVD Risk Calculator Application
...... version Σ 0..1 string Version of the system - if relevant
...... code SOΣ 1..1 code Symbol in syntax defined by the system
Fixed Value: 163035008
ObligationsActor
SHALL:populate-if-known Aus CVD Risk Calculator Launch Server
SHALL:process Aus CVD Risk Calculator Application
...... display Σ 0..1 string Representation defined by the system
...... userSelected Σ 0..1 boolean If this coding was chosen directly by the user
.... text Σ 0..1 string Plain text representation of the concept
... subject SOΣ 1..1 Reference(AU Core Patient) Who and/or what the observation is about
ObligationsActor
SHALL:populate-if-known AU Core Responder from AU Core Blood Pressure
SHALL:no-error AU Core Requester from AU Core Blood Pressure
SHALL:populate-if-known & SHALL:process AU Core ResponderAus CVD Risk Calculator Application
SHALL:no-error AU Core Requester
... focus Σ 0..* Reference(Resource) What the observation is about, when it is not about the subject of record
... encounter Σ 0..1 Reference(Encounter) Healthcare event during which this observation is made
... effective[x] SOΣC 1..1 dateTime Date, and optionally time, the observation was performed
vs-1: if Observation.effective[x] is dateTime and has a value then that value shall be precise to the day
ObligationsActor
SHALL:populate-if-known AU Core Responder from AU Core Blood Pressure
SHALL:no-error AU Core Requester from AU Core Blood Pressure
... issued Σ 0..1 instant Date/Time this version was made available
... performer Σ 0..* Reference(Practitioner | PractitionerRole | Organization | CareTeam | Patient | RelatedPerson) Who is responsible for the observation
... Slices for value[x] SΣC 0..1 Quantity Vital Signs value are recorded using the Quantity data type. For supporting observations such as Cuff size could use other datatypes such as CodeableConcept.
Slice: Unordered, Closed by type:$this
... dataAbsentReason SOC 0..1 CodeableConcept Why the result is missing
Binding: DataAbsentReason (extensible): Codes specifying why the result (Observation.value[x]) is missing.

ObligationsActor
SHALL:populate-if-known AU Core Responder from AU Core Blood Pressure
SHALL:no-error AU Core Requester from AU Core Blood Pressure
... interpretation 0..* CodeableConcept High, low, normal, etc.
Binding: ObservationInterpretationCodes (extensible): Codes identifying interpretations of observations.


... note 0..* Annotation Comments about the observation
... bodySite C 0..1 CodeableConcept Observed body part
Binding: Body Site . (extensible)
au-core-obs-01: If a coded body site is provided, at least one coding shall be from SNOMED CT
... method 0..1 CodeableConcept How it was done
Binding: ObservationMethods (example): Methods for simple observations.

... specimen 0..1 Reference(Specimen) Specimen used for this observation
... device 0..1 Reference(Device | DeviceMetric) (Measurement) Device
... referenceRange C 0..* BackboneElement Provides guide for interpretation
obs-3: Must have at least a low or a high or text
.... id 0..1 string Unique id for inter-element referencing
.... extension 0..* Extension Additional content defined by implementations
.... modifierExtension ?!Σ 0..* Extension Extensions that cannot be ignored even if unrecognized
.... low C 0..1 SimpleQuantity Low Range, if relevant
.... high C 0..1 SimpleQuantity High Range, if relevant
.... type 0..1 CodeableConcept Reference range qualifier
Binding: ObservationReferenceRangeMeaningCodes (preferred): Code for the meaning of a reference range.

.... appliesTo 0..* CodeableConcept Reference range population
Binding: ObservationReferenceRangeAppliesToCodes (example): Codes identifying the population the reference range applies to.


.... age 0..1 Range Applicable age range, if relevant
.... text 0..1 string Text based reference range in an observation
... hasMember Σ 0..* Reference(QuestionnaireResponse | MolecularSequence | Vital Signs Profile) Used when reporting vital signs panel components
... derivedFrom Σ 0..* Reference(DocumentReference | ImagingStudy | Media | QuestionnaireResponse | MolecularSequence | Vital Signs Profile) Related measurements the observation is made from
... Slices for component SOΣC 2..* BackboneElement Used when reporting systolic and diastolic blood pressure.
Slice: Unordered, Open by value:code.coding.code, value:code.coding.system
vs-3: If there is no a value a data absent reason must be present
ObligationsActor
SHALL:populate-if-known AU Core Responder from AU Core Blood Pressure
SHALL:no-error AU Core Requester from AU Core Blood Pressure
SHALL:populate-if-known & SHALL:process AU Core ResponderAus CVD Risk Calculator Application
SHALL:no-error AU Core Requester
.... component:All Slices Content/Rules for all slices
..... id 0..1 string Unique id for inter-element referencing
..... extension 0..* Extension Additional content defined by implementations
..... modifierExtension ?!Σ 0..* Extension Extensions that cannot be ignored even if unrecognized
..... code SOΣ 1..1 CodeableConcept Type of component observation (code / type)
Binding: VitalSigns (extensible): This identifies the vital sign result type.

ObligationsActor
SHALL:populate-if-known AU Core Responder from AU Core Blood Pressure
SHALL:no-error AU Core Requester from AU Core Blood Pressure
..... value[x] SOΣC 0..1 Vital Sign Value recorded with UCUM
Binding: VitalSignsUnits (extensible): Common UCUM units for recording Vital Signs.

ObligationsActor
SHALL:populate-if-known AU Core Responder from AU Core Blood Pressure
SHALL:no-error AU Core Requester from AU Core Blood Pressure
...... valueQuantity Quantity
...... valueCodeableConcept CodeableConcept
...... valueString string
...... valueBoolean boolean
...... valueInteger integer
...... valueRange Range
...... valueRatio Ratio
...... valueSampledData SampledData
...... valueTime time
...... valueDateTime dateTime
...... valuePeriod Period
..... dataAbsentReason SOC 0..1 CodeableConcept Why the component result is missing
Binding: DataAbsentReason (extensible): Codes specifying why the result (Observation.value[x]) is missing.

ObligationsActor
SHALL:populate-if-known AU Core Responder from AU Core Blood Pressure
SHALL:no-error AU Core Requester from AU Core Blood Pressure
..... interpretation 0..* CodeableConcept High, low, normal, etc.
Binding: ObservationInterpretationCodes (extensible): Codes identifying interpretations of observations.


..... referenceRange 0..* See referenceRange (Observation) Provides guide for interpretation of component result
.... component:SystolicBP SOΣC 1..1 BackboneElement Systolic Blood Pressure
vs-3: If there is no a value a data absent reason must be present
ObligationsActor
SHALL:populate-if-known AU Core Responder from AU Core Blood Pressure
SHALL:no-error AU Core Requester from AU Core Blood Pressure
..... id 0..1 string Unique id for inter-element referencing
..... extension 0..* Extension Additional content defined by implementations
..... modifierExtension ?!Σ 0..* Extension Extensions that cannot be ignored even if unrecognized
..... code SOΣ 1..1 CodeableConcept Type of component observation (code / type)
Binding: VitalSigns (extensible): This identifies the vital sign result type.

ObligationsActor
SHALL:populate-if-known AU Core Responder from AU Core Blood Pressure
SHALL:no-error AU Core Requester from AU Core Blood Pressure
...... id 0..1 string Unique id for inter-element referencing
...... extension 0..* Extension Additional content defined by implementations
Slice: Unordered, Open by value:url
...... Slices for coding Σ 3..* Coding Systolic Blood Pressure
Slice: Unordered, Open by value:code, value:system
....... coding:SBPCode Σ 1..1 Coding Systolic Blood Pressure
........ id 0..1 string Unique id for inter-element referencing
........ extension 0..* Extension Additional content defined by implementations
Slice: Unordered, Open by value:url
........ system Σ 1..1 uri Identity of the terminology system
Fixed Value: http://loinc.org
........ version Σ 0..1 string Version of the system - if relevant
........ code Σ 1..1 code Symbol in syntax defined by the system
Fixed Value: 8480-6
........ display Σ 0..1 string Representation defined by the system
........ userSelected Σ 0..1 boolean If this coding was chosen directly by the user
....... coding:snomedSBP Σ 1..1 Coding SNOMED CT Systolic Blood Pressure
........ id 0..1 string Unique id for inter-element referencing
........ extension 0..* Extension Additional content defined by implementations
Slice: Unordered, Open by value:url
........ system Σ 1..1 uri Identity of the terminology system
Fixed Value: http://snomed.info/sct
........ version Σ 0..1 string Version of the system - if relevant
........ code Σ 1..1 code Symbol in syntax defined by the system
Fixed Value: 271649006
........ display Σ 0..1 string Representation defined by the system
........ userSelected Σ 0..1 boolean If this coding was chosen directly by the user
....... coding:snomedSittingSBP SOΣ 1..1 Coding SNOMED CT Sitting Systolic Blood Pressure
ObligationsActor
SHALL:populate-if-known Aus CVD Risk Calculator Launch Server
SHALL:process Aus CVD Risk Calculator Application
........ id 0..1 string Unique id for inter-element referencing
........ extension 0..* Extension Additional content defined by implementations
Slice: Unordered, Open by value:url
........ system SOΣ 1..1 uri Identity of the terminology system
Fixed Value: http://snomed.info/sct
ObligationsActor
SHALL:populate-if-known Aus CVD Risk Calculator Launch Server
SHALL:process Aus CVD Risk Calculator Application
........ version Σ 0..1 string Version of the system - if relevant
........ code SOΣ 1..1 code Symbol in syntax defined by the system
Fixed Value: 407554009
ObligationsActor
SHALL:populate-if-known Aus CVD Risk Calculator Launch Server
SHALL:process Aus CVD Risk Calculator Application
........ display Σ 0..1 string Representation defined by the system
........ userSelected Σ 0..1 boolean If this coding was chosen directly by the user
...... text Σ 0..1 string Plain text representation of the concept
..... value[x] SOΣC 0..1 Quantity Vital Sign Value recorded with UCUM
Binding: VitalSignsUnits (extensible): Common UCUM units for recording Vital Signs.

ObligationsActor
SHALL:populate-if-known AU Core Responder from AU Core Blood Pressure
SHALL:no-error AU Core Requester from AU Core Blood Pressure
...... id 0..1 string Unique id for inter-element referencing
...... extension 0..* Extension Additional content defined by implementations
Slice: Unordered, Open by value:url
...... value SOΣ 1..1 decimal Numerical value (with implicit precision)
ObligationsActor
SHALL:populate-if-known AU Core Responder from AU Core Blood Pressure
SHALL:no-error AU Core Requester from AU Core Blood Pressure
...... comparator ?!Σ 0..1 code < | <= | >= | > - how to understand the value
Binding: QuantityComparator (required): How the Quantity should be understood and represented.

...... unit SOΣ 1..1 string Unit representation
ObligationsActor
SHALL:populate-if-known AU Core Responder from AU Core Blood Pressure
SHALL:no-error AU Core Requester from AU Core Blood Pressure
...... system SOΣC 1..1 uri System that defines coded unit form
Fixed Value: http://unitsofmeasure.org
ObligationsActor
SHALL:populate-if-known AU Core Responder from AU Core Blood Pressure
SHALL:no-error AU Core Requester from AU Core Blood Pressure
...... code SOΣ 1..1 code Coded responses from the common UCUM units for vital signs value set.
Fixed Value: mm[Hg]
ObligationsActor
SHALL:populate-if-known AU Core Responder from AU Core Blood Pressure
SHALL:no-error AU Core Requester from AU Core Blood Pressure
..... dataAbsentReason SOC 0..1 CodeableConcept Why the component result is missing
Binding: DataAbsentReason (extensible): Codes specifying why the result (Observation.value[x]) is missing.

ObligationsActor
SHALL:populate-if-known AU Core Responder from AU Core Blood Pressure
SHALL:no-error AU Core Requester from AU Core Blood Pressure
..... interpretation 0..* CodeableConcept High, low, normal, etc.
Binding: ObservationInterpretationCodes (extensible): Codes identifying interpretations of observations.


..... referenceRange 0..* See referenceRange (Observation) Provides guide for interpretation of component result
.... component:DiastolicBP SOΣC 1..1 BackboneElement Diastolic Blood Pressure
vs-3: If there is no a value a data absent reason must be present
ObligationsActor
SHALL:populate-if-known AU Core Responder from AU Core Blood Pressure
SHALL:no-error AU Core Requester from AU Core Blood Pressure
..... id 0..1 string Unique id for inter-element referencing
..... extension 0..* Extension Additional content defined by implementations
..... modifierExtension ?!Σ 0..* Extension Extensions that cannot be ignored even if unrecognized
..... code SOΣ 1..1 CodeableConcept Type of component observation (code / type)
Binding: VitalSigns (extensible): This identifies the vital sign result type.

ObligationsActor
SHALL:populate-if-known AU Core Responder from AU Core Blood Pressure
SHALL:no-error AU Core Requester from AU Core Blood Pressure
...... id 0..1 string Unique id for inter-element referencing
...... extension 0..* Extension Additional content defined by implementations
Slice: Unordered, Open by value:url
...... Slices for coding Σ 3..* Coding Diastolic Blood Pressure
Slice: Unordered, Open by value:code, value:system
....... coding:DBPCode Σ 1..1 Coding Diastolic Blood Pressure
........ id 0..1 string Unique id for inter-element referencing
........ extension 0..* Extension Additional content defined by implementations
Slice: Unordered, Open by value:url
........ system Σ 1..1 uri Identity of the terminology system
Fixed Value: http://loinc.org
........ version Σ 0..1 string Version of the system - if relevant
........ code Σ 1..1 code Symbol in syntax defined by the system
Fixed Value: 8462-4
........ display Σ 0..1 string Representation defined by the system
........ userSelected Σ 0..1 boolean If this coding was chosen directly by the user
....... coding:snomedDBP Σ 1..1 Coding SNOMED CT Diastolic Blood Pressure
........ id 0..1 string Unique id for inter-element referencing
........ extension 0..* Extension Additional content defined by implementations
Slice: Unordered, Open by value:url
........ system Σ 1..1 uri Identity of the terminology system
Fixed Value: http://snomed.info/sct
........ version Σ 0..1 string Version of the system - if relevant
........ code Σ 1..1 code Symbol in syntax defined by the system
Fixed Value: 271650006
........ display Σ 0..1 string Representation defined by the system
........ userSelected Σ 0..1 boolean If this coding was chosen directly by the user
....... coding:snomedSittingDBP SOΣ 1..1 Coding SNOMED CT Sitting Diastolic Blood Pressure
ObligationsActor
SHALL:populate-if-known Aus CVD Risk Calculator Launch Server
SHALL:process Aus CVD Risk Calculator Application
........ id 0..1 string Unique id for inter-element referencing
........ extension 0..* Extension Additional content defined by implementations
Slice: Unordered, Open by value:url
........ system SOΣ 1..1 uri Identity of the terminology system
Fixed Value: http://snomed.info/sct
ObligationsActor
SHALL:populate-if-known Aus CVD Risk Calculator Launch Server
SHALL:no-error Aus CVD Risk Calculator Application
........ version Σ 0..1 string Version of the system - if relevant
........ code SOΣ 1..1 code Symbol in syntax defined by the system
Fixed Value: 407555005
ObligationsActor
SHALL:populate-if-known Aus CVD Risk Calculator Launch Server
SHALL:no-error Aus CVD Risk Calculator Application
........ display Σ 0..1 string Representation defined by the system
........ userSelected Σ 0..1 boolean If this coding was chosen directly by the user
...... text Σ 0..1 string Plain text representation of the concept
..... value[x] SOΣC 0..1 Quantity Vital Sign Value recorded with UCUM
Binding: VitalSignsUnits (extensible): Common UCUM units for recording Vital Signs.

ObligationsActor
SHALL:populate-if-known AU Core Responder from AU Core Blood Pressure
SHALL:no-error AU Core Requester from AU Core Blood Pressure
...... id 0..1 string Unique id for inter-element referencing
...... extension 0..* Extension Additional content defined by implementations
Slice: Unordered, Open by value:url
...... value SOΣ 1..1 decimal Numerical value (with implicit precision)
ObligationsActor
SHALL:populate-if-known AU Core Responder from AU Core Blood Pressure
SHALL:no-error AU Core Requester from AU Core Blood Pressure
...... comparator ?!Σ 0..1 code < | <= | >= | > - how to understand the value
Binding: QuantityComparator (required): How the Quantity should be understood and represented.

...... unit SOΣ 1..1 string Unit representation
ObligationsActor
SHALL:populate-if-known AU Core Responder from AU Core Blood Pressure
SHALL:no-error AU Core Requester from AU Core Blood Pressure
...... system SOΣC 1..1 uri System that defines coded unit form
Fixed Value: http://unitsofmeasure.org
ObligationsActor
SHALL:populate-if-known AU Core Responder from AU Core Blood Pressure
SHALL:no-error AU Core Requester from AU Core Blood Pressure
...... code SOΣ 1..1 code Coded responses from the common UCUM units for vital signs value set.
Fixed Value: mm[Hg]
ObligationsActor
SHALL:populate-if-known AU Core Responder from AU Core Blood Pressure
SHALL:no-error AU Core Requester from AU Core Blood Pressure
..... dataAbsentReason SOC 0..1 CodeableConcept Why the component result is missing
Binding: DataAbsentReason (extensible): Codes specifying why the result (Observation.value[x]) is missing.

ObligationsActor
SHALL:populate-if-known AU Core Responder from AU Core Blood Pressure
SHALL:no-error AU Core Requester from AU Core Blood Pressure
..... interpretation 0..* CodeableConcept High, low, normal, etc.
Binding: ObservationInterpretationCodes (extensible): Codes identifying interpretations of observations.


..... referenceRange 0..* See referenceRange (Observation) Provides guide for interpretation of component result

doco Documentation for this format

Terminology Bindings

PathConformanceValueSet / CodeURI
Observation.languagepreferredCommonLanguages
http://hl7.org/fhir/ValueSet/languages
from the FHIR Standard
Additional Bindings Purpose
AllLanguages Max Binding
Observation.statusrequiredFixed Value: final
http://hl7.org/fhir/ValueSet/observation-status|4.0.1
from the FHIR Standard
Observation.categorypreferredObservationCategoryCodes
http://hl7.org/fhir/ValueSet/observation-category
from the FHIR Standard
Observation.category:VSCatpreferredObservationCategoryCodes
http://hl7.org/fhir/ValueSet/observation-category
from the FHIR Standard
Observation.codeextensibleVitalSigns
http://hl7.org/fhir/ValueSet/observation-vitalsignresult
from the FHIR Standard
Observation.dataAbsentReasonextensibleDataAbsentReason
http://hl7.org/fhir/ValueSet/data-absent-reason
from the FHIR Standard
Observation.interpretationextensibleObservationInterpretationCodes
http://hl7.org/fhir/ValueSet/observation-interpretation
from the FHIR Standard
Observation.bodySiteextensibleBodySite .
https://healthterminologies.gov.au/fhir/ValueSet/body-site-1
Observation.methodexampleObservationMethods
http://hl7.org/fhir/ValueSet/observation-methods
from the FHIR Standard
Observation.referenceRange.typepreferredObservationReferenceRangeMeaningCodes
http://hl7.org/fhir/ValueSet/referencerange-meaning
from the FHIR Standard
Observation.referenceRange.appliesToexampleObservationReferenceRangeAppliesToCodes
http://hl7.org/fhir/ValueSet/referencerange-appliesto
from the FHIR Standard
Observation.component.codeextensibleVitalSigns
http://hl7.org/fhir/ValueSet/observation-vitalsignresult
from the FHIR Standard
Observation.component.value[x]extensibleVitalSignsUnits
http://hl7.org/fhir/ValueSet/ucum-vitals-common|4.0.1
from the FHIR Standard
Observation.component.dataAbsentReasonextensibleDataAbsentReason
http://hl7.org/fhir/ValueSet/data-absent-reason
from the FHIR Standard
Observation.component.interpretationextensibleObservationInterpretationCodes
http://hl7.org/fhir/ValueSet/observation-interpretation
from the FHIR Standard
Observation.component:SystolicBP.codeextensibleVitalSigns
http://hl7.org/fhir/ValueSet/observation-vitalsignresult
from the FHIR Standard
Observation.component:SystolicBP.value[x]extensibleVitalSignsUnits
http://hl7.org/fhir/ValueSet/ucum-vitals-common|4.0.1
from the FHIR Standard
Observation.component:SystolicBP.value[x].comparatorrequiredQuantityComparator
http://hl7.org/fhir/ValueSet/quantity-comparator|4.0.1
from the FHIR Standard
Observation.component:SystolicBP.dataAbsentReasonextensibleDataAbsentReason
http://hl7.org/fhir/ValueSet/data-absent-reason
from the FHIR Standard
Observation.component:SystolicBP.interpretationextensibleObservationInterpretationCodes
http://hl7.org/fhir/ValueSet/observation-interpretation
from the FHIR Standard
Observation.component:DiastolicBP.codeextensibleVitalSigns
http://hl7.org/fhir/ValueSet/observation-vitalsignresult
from the FHIR Standard
Observation.component:DiastolicBP.value[x]extensibleVitalSignsUnits
http://hl7.org/fhir/ValueSet/ucum-vitals-common|4.0.1
from the FHIR Standard
Observation.component:DiastolicBP.value[x].comparatorrequiredQuantityComparator
http://hl7.org/fhir/ValueSet/quantity-comparator|4.0.1
from the FHIR Standard
Observation.component:DiastolicBP.dataAbsentReasonextensibleDataAbsentReason
http://hl7.org/fhir/ValueSet/data-absent-reason
from the FHIR Standard
Observation.component:DiastolicBP.interpretationextensibleObservationInterpretationCodes
http://hl7.org/fhir/ValueSet/observation-interpretation
from the FHIR Standard

Constraints

IdGradePath(s)DetailsRequirements
au-core-obs-01errorObservation.bodySiteIf a coded body site is provided, at least one coding shall be from SNOMED CT
: coding.exists() implies coding.where(system='http://snomed.info/sct').exists()
dom-2errorObservationIf the resource is contained in another resource, it SHALL NOT contain nested Resources
: contained.contained.empty()
dom-3errorObservationIf the resource is contained in another resource, it SHALL be referred to from elsewhere in the resource or SHALL refer to the containing resource
: contained.where((('#'+id in (%resource.descendants().reference | %resource.descendants().as(canonical) | %resource.descendants().as(uri) | %resource.descendants().as(url))) or descendants().where(reference = '#').exists() or descendants().where(as(canonical) = '#').exists() or descendants().where(as(canonical) = '#').exists()).not()).trace('unmatched', id).empty()
dom-4errorObservationIf a resource is contained in another resource, it SHALL NOT have a meta.versionId or a meta.lastUpdated
: contained.meta.versionId.empty() and contained.meta.lastUpdated.empty()
dom-5errorObservationIf a resource is contained in another resource, it SHALL NOT have a security label
: contained.meta.security.empty()
dom-6best practiceObservationA resource should have narrative for robust management
: text.`div`.exists()
ele-1error**ALL** elementsAll FHIR elements must have a @value or children
: hasValue() or (children().count() > id.count())
ext-1error**ALL** extensionsMust have either extensions or value[x], not both
: extension.exists() != value.exists()
obs-3errorObservation.referenceRangeMust have at least a low or a high or text
: low.exists() or high.exists() or text.exists()
obs-6errorObservationdataAbsentReason SHALL only be present if Observation.value[x] is not present
: dataAbsentReason.empty() or value.empty()
obs-7errorObservationIf Observation.code is the same as an Observation.component.code then the value element associated with the code SHALL NOT be present
: value.empty() or component.code.where(coding.intersect(%resource.code.coding).exists()).empty()
vs-1errorObservation.effective[x]if Observation.effective[x] is dateTime and has a value then that value shall be precise to the day
: $this is dateTime implies $this.toString().length() >= 10
vs-2errorObservationIf there is no component or hasMember element then either a value[x] or a data absent reason must be present.
: (component.empty() and hasMember.empty()) implies (dataAbsentReason.exists() or value.exists())
vs-3errorObservation.component, Observation.component:SystolicBP, Observation.component:DiastolicBPIf there is no a value a data absent reason must be present
: value.exists() or dataAbsentReason.exists()

This structure is derived from AUCoreBloodPressure

Summary

Mandatory: 9 elements
Must-Support: 9 elements
Fixed: 7 elements

 

Other representations of profile: CSV, Excel, Schematron